Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.157 kW
07/16/2026 16:43 (2241 days) Production Consumption NET Usage
Now 1.658 kW 0.501 kW -1.157 kW
Today 19.044 kWh (1.138 kW) 19.589 kWh (1.170 kW) 0.545 kWh (0.033 kW)
  - This Week 142.422 kWh (30.323 kWh/day) 157.035 kWh (33.434 kWh/day) 14.613 kWh (3.111 kWh/day)
  - This Month 412.976 kWh (26.308 kWh/day) 554.998 kWh (35.356 kWh/day) 142.022 kWh (9.047 kWh/day)
  - This Year 4.023 MWh (20.452 kWh/day) 3.842 MWh (19.531 kWh/day) -0.181 MWh (-0.920 kWh/day)
Yesterday 27.130 kWh (1.130 kW) 32.592 kWh (1.358 kW) 5.462 kWh (0.228 kW)
Last 7 Days 197.914 kWh (28.273 kWh/day) 236.202 kWh (33.743 kWh/day) 38.288 kWh (5.470 kWh/day)
Last 30 Days (06/16/2026) 742.011 kWh (24.734 kWh/day) 851.086 kWh (28.370 kWh/day) 109.075 kWh (3.636 kWh/day)
Last One Year 6.727 MWh (18.431 kWh/day) 7.655 MWh (20.972 kWh/day) 0.927 MWh (2.541 kWh/day)
Lifetime Since PTO 39.588 MWh (17.660 kW/day) 43.353 MWh (19.339 kW/day) 3.764 MWh (1.679 kW/day)
Lifetime Since Install 39.622 MWh 43.933 MWh 4.310 MWh
Voltage/Current 124.9 V / 6.6 A, 124.9 V / 6.6 A 124.9 V / 2.7 A, 124.8 V / 1.3 A 124.9 V / -3.9 A, 124.9 V / -5.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/16/2023 23:53 (15.9 hours) Number of Devices 18 set
Current Power 0.229 kW (0.013 kW/panel) Today Energy 14.306 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.198 1.009 0.983 5.577 0.000 kW
0.994 kWh
0.000 kW
5.967 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.189 0.973 0.929 5.304
03 - 202224****** IQ7+M [5] VCOP 0.000 0.194 1.007 0.972 5.545
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 1.010 0.975 5.576
05 - 202244****** IQ7+M [5] VCOP 0.000 0.190 0.983 0.939 5.372
06 - 202245****** IQ7+M [5] VCOP 0.000 0.192 0.985 0.948 5.442
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.248 1.037 0.914 5.568 0.000 kW
1.184 kWh
0.000 kW
5.920 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.248 1.174 1.073 6.219
09 - 202217****** IQ7+ [5] VCOP 0.000 0.248 1.257 1.160 6.763
10 - 202244****** IQ7+M [5] VCOP 0.000 0.245 1.246 1.142 6.600
11 - 202224****** IQ7+M [5] VCOP 0.000 0.250 1.207 1.084 6.327
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.094 0.422 0.663 2.976 0.000 kW
0.489 kWh
0.000 kW
1.957 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.099 0.499 0.718 3.351
14 - 202216****** IQ7+ [5] VCOP 0.000 0.102 0.523 0.680 3.447
15 - 202245****** IQ7+M [5] VCOP 0.000 0.102 0.512 0.631 3.361
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.076 kW
0.154 kWh
0.229 kW
0.463 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.229 0.230 0.463 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.