Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.452 kW
07/16/2026 12:15 (2241 days) Production Consumption NET Usage
Now 2.433 kW 3.885 kW 1.452 kW
Today 7.991 kWh (0.651 kW) 10.211 kWh (0.832 kW) 2.220 kWh (0.181 kW)
  - This Week 131.369 kWh (29.122 kWh/day) 147.657 kWh (32.733 kWh/day) 16.288 kWh (3.611 kWh/day)
  - This Month 401.923 kWh (25.911 kWh/day) 545.620 kWh (35.175 kWh/day) 143.697 kWh (9.264 kWh/day)
  - This Year 4.012 MWh (20.415 kWh/day) 3.832 MWh (19.502 kWh/day) -0.179 MWh (-0.913 kWh/day)
Yesterday 27.130 kWh (1.130 kW) 32.592 kWh (1.358 kW) 5.462 kWh (0.228 kW)
Last 7 Days 193.911 kWh (27.702 kWh/day) 234.927 kWh (33.561 kWh/day) 41.016 kWh (5.859 kWh/day)
Last 30 Days (06/16/2026) 748.414 kWh (24.947 kWh/day) 841.316 kWh (28.044 kWh/day) 92.902 kWh (3.097 kWh/day)
Last One Year 6.730 MWh (18.439 kWh/day) 7.656 MWh (20.976 kWh/day) 0.926 MWh (2.537 kWh/day)
Lifetime Since PTO 39.577 MWh (17.657 kW/day) 43.343 MWh (19.337 kW/day) 3.766 MWh (1.680 kW/day)
Lifetime Since Install 39.611 MWh 43.923 MWh 4.312 MWh
Voltage/Current 123.9 V / 9.8 A, 123.9 V / 9.8 A 123.1 V / 21.8 A, 124.6 V / 9.6 A 123.5 V / 11.9 A, 124.2 V / -0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/29/2024 23:18 (9.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.811 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.049 0.201 0.133 2.074 0.000 kW
0.190 kWh
0.000 kW
1.141 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.046 0.183 0.120 2.018
03 - 202224****** IQ7+M [5] VCOP 0.000 0.049 0.198 0.132 2.074
04 - 202232****** IQ7+ [5] VCOP 0.000 0.049 0.197 0.129 2.158
05 - 202244****** IQ7+M [5] VCOP 0.000 0.045 0.179 0.118 1.973
06 - 202245****** IQ7+M [5] VCOP 0.000 0.047 0.184 0.121 2.049
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.044 0.179 0.118 2.162 0.000 kW
0.181 kWh
0.000 kW
0.904 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.045 0.182 0.121 2.354
09 - 202217****** IQ7+ [5] VCOP 0.000 0.045 0.179 0.119 2.420
10 - 202244****** IQ7+M [5] VCOP 0.000 0.045 0.180 0.120 2.406
11 - 202224****** IQ7+M [5] VCOP 0.000 0.045 0.184 0.121 2.351
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.044 0.174 0.116 1.285 0.000 kW
0.192 kWh
0.000 kW
0.767 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.047 0.191 0.127 1.359
14 - 202216****** IQ7+ [5] VCOP 0.000 0.048 0.201 0.135 1.432
15 - 202245****** IQ7+M [5] VCOP 0.000 0.049 0.201 0.134 1.447
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Battery History
Voltage 53.19 V Current/Power -1.08 A (-57 W)
Remain Capacity/Energy 399.3 Ah (20.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 67.3 % State Of Health 98.9 %
Run Time 15d 9h 43m to empty Report Date 2024-01-29 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.