| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 2.340 kW | |||
|---|---|---|---|
| 07/15/2026 22:17 (2240 days) | Production | Consumption | NET Usage |
| Now | 0.225 kW | 2.565 kW | 2.340 kW |
| Today | 26.749 kWh (1.199 kW) | 30.769 kWh (1.379 kW) | 4.020 kWh (0.180 kW) |
| - This Week | 122.997 kWh (31.306 kWh/day) | 135.623 kWh (34.519 kWh/day) | 12.626 kWh (3.214 kWh/day) |
| - This Month | 393.551 kWh (26.360 kWh/day) | 533.586 kWh (35.740 kWh/day) | 140.035 kWh (9.380 kWh/day) |
| - This Year | 4.003 MWh (20.433 kWh/day) | 3.820 MWh (19.499 kWh/day) | -0.183 MWh (-0.934 kWh/day) |
| Yesterday | 32.213 kWh (1.343 kW) | 36.111 kWh (1.506 kW) | 3.898 kWh (0.163 kW) |
| Last 7 Days | 197.846 kWh (28.264 kWh/day) | 235.147 kWh (33.592 kWh/day) | 37.301 kWh (5.329 kWh/day) |
| Last 30 Days (06/15/2026) | 752.287 kWh (25.076 kWh/day) | 831.105 kWh (27.704 kWh/day) | 78.818 kWh (2.627 kWh/day) |
| Last One Year | 6.732 MWh (18.443 kWh/day) | 7.659 MWh (20.983 kWh/day) | 0.927 MWh (2.541 kWh/day) |
| Lifetime Since PTO | 39.569 MWh (17.657 kW/day) | 43.331 MWh (19.336 kW/day) | 3.762 MWh (1.679 kW/day) |
| Lifetime Since Install | 39.603 MWh | 43.911 MWh | 4.308 MWh |
| Voltage/Current | 124.8 V / 0.9 A, 124.8 V / 0.9 A | 124.6 V / 10.5 A, 124.9 V / 10.1 A | 124.7 V / 9.6 A, 124.8 V / 9.2 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 04/19/2025 23:44 (12.7 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 18.414 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.274 | 1.306 | 1.926 | 8.646 | 0.000 kW 1.273 kWh |
0.000 kW 7.637 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.261 | 1.242 | 1.829 | 8.265 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.272 | 1.288 | 1.920 | 8.178 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.269 | 1.296 | 1.977 | 8.862 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.262 | 1.236 | 1.733 | 8.359 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.270 | 1.268 | 1.818 | 8.490 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.285 | 1.302 | 1.758 | 8.812 | 0.000 kW 1.310 kWh |
0.000 kW 6.552 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.285 | 1.307 | 1.826 | 8.603 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.283 | 1.305 | 1.821 | 8.624 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.277 | 1.311 | 1.824 | 8.657 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.280 | 1.328 | 1.847 | 8.962 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.227 | 1.026 | 1.801 | 7.796 | 0.000 kW 1.056 kWh |
0.000 kW 4.225 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.231 | 1.045 | 1.843 | 8.085 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.232 | 1.078 | 1.880 | 8.293 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.231 | 1.076 | 1.884 | 8.267 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.48 V | Voltage Charge | 52.13 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 28.6 °C / 25.6 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-04-19 23:58 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.39 V | Current/Power | -11.30 A (-0.592 kW) |
| Remain Capacity/Energy | 275.2 Ah (14.1 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 46.4 % | State Of Health | 98.9 % |
| Run Time | 1d 0h 21m to empty | Report Date | 2025-04-19 23:57 |
|
|||
| Voltage | 52.35 V | Cell (MIN/MAX) | 3.266 V / 3.276 V (0.010 V) |
|---|---|---|---|
| Current/Power | -3.10 A (-162 W) | Runtime | 1d 5h 35m to empty |
| Remain Capacity/Energy | 91.8 Ah (4.7 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 46.4 % | State Of Health | 98.8 % |
| Temperature | 20.0 °C | Cycle | 191 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-04-19 23:57 |
| Voltage | 52.41 V | Cell (MIN/MAX) | 3.275 V / 3.276 V (0.001 V) |
|---|---|---|---|
| Current/Power | -2.05 A (-107 W) | Runtime | 1d 11h 47m to empty |
| Remain Capacity/Energy | 73.5 Ah (3.8 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 73.9 % | State Of Health | 99.5 % |
| Temperature | 22.1 °C | Cycle | 125 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-04-19 23:58 |
| Voltage | 52.43 V | Cell (MIN/MAX) | 3.276 V / 3.276 V (0.000 V) |
|---|---|---|---|
| Current/Power | -2.01 A (-105 W) | Runtime | 1d 12h 14m to empty |
| Remain Capacity/Energy | 72.9 Ah (3.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 73.3 % | State Of Health | 99.5 % |
| Temperature | 20.9 °C | Cycle | 129 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-04-19 23:58 |
| Voltage | 52.40 V | Cell (MIN/MAX) | 3.273 V / 3.275 V (0.002 V) |
|---|---|---|---|
| Current/Power | -1.97 A (-103 W) | Runtime | 1d 13h 15m to empty |
| Remain Capacity/Energy | 73.4 Ah (3.8 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 73.8 % | State Of Health | 99.5 % |
| Temperature | 21.0 °C | Cycle | 131 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-04-19 23:57 |
| Voltage | 52.39 V | Cell (MIN/MAX) | 3.273 V / 3.275 V (0.002 V) |
|---|---|---|---|
| Current/Power | -2.10 A (-110 W) | Runtime | 1d 10h 14m to empty |
| Remain Capacity/Energy | 71.9 Ah (3.7 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 72.5 % | State Of Health | 99.2 % |
| Temperature | 21.9 °C | Cycle | 130 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-04-19 23:58 |