Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.282 kW
07/15/2026 18:24 (2240 days) Production Consumption NET Usage
Now 0.335 kW 2.617 kW 2.282 kW
Today 25.775 kWh (1.399 kW) 23.512 kWh (1.276 kW) -2.263 kWh (-0.123 kW)
  - This Week 122.023 kWh (32.395 kWh/day) 128.366 kWh (34.079 kWh/day) 6.343 kWh (1.684 kWh/day)
  - This Month 392.577 kWh (26.584 kWh/day) 526.329 kWh (35.641 kWh/day) 133.752 kWh (9.057 kWh/day)
  - This Year 4.002 MWh (20.445 kWh/day) 3.813 MWh (19.478 kWh/day) -0.189 MWh (-0.967 kWh/day)
Yesterday 32.213 kWh (1.343 kW) 36.111 kWh (1.506 kW) 3.898 kWh (0.163 kW)
Last 7 Days 198.573 kWh (28.368 kWh/day) 237.040 kWh (33.863 kWh/day) 38.467 kWh (5.495 kWh/day)
Last 30 Days (06/15/2026) 752.278 kWh (25.076 kWh/day) 826.415 kWh (27.547 kWh/day) 74.137 kWh (2.471 kWh/day)
Last One Year 6.731 MWh (18.441 kWh/day) 7.660 MWh (20.985 kWh/day) 0.929 MWh (2.544 kWh/day)
Lifetime Since PTO 39.568 MWh (17.658 kW/day) 43.324 MWh (19.334 kW/day) 3.756 MWh (1.676 kW/day)
Lifetime Since Install 39.602 MWh 43.904 MWh 4.302 MWh
Voltage/Current 124.6 V / 1.3 A, 124.6 V / 1.3 A 124.6 V / 10.8 A, 124.3 V / 10.2 A 124.6 V / 9.4 A, 124.4 V / 8.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/10/2025 23:45 (23.6 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 19.466 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.210 0.984 1.853 10.691 0.000 kW
0.960 kWh
0.000 kW
5.759 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.937 1.778 10.249
03 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.976 1.854 10.692
04 - 202232****** IQ7+ [5] VCOP 0.000 0.208 0.976 1.877 10.842
05 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.929 1.720 9.946
06 - 202245****** IQ7+M [5] VCOP 0.000 0.202 0.957 1.759 10.204
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.201 0.922 1.770 10.330 0.000 kW
0.931 kWh
0.000 kW
4.657 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.205 0.933 1.892 10.798
09 - 202217****** IQ7+ [5] VCOP 0.000 0.207 0.933 1.864 10.662
10 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.930 1.897 10.869
11 - 202224****** IQ7+M [5] VCOP 0.000 0.208 0.940 1.924 11.016
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.171 0.848 1.531 8.888 0.000 kW
0.888 kWh
0.000 kW
3.553 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.179 0.879 1.557 9.048
14 - 202216****** IQ7+ [5] VCOP 0.000 0.178 0.913 1.606 9.337
15 - 202245****** IQ7+M [5] VCOP 0.000 0.179 0.913 1.603 9.355
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.832 kWh
0.230 kW
5.497 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.497 5.500 38.518
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Charger History
Voltage PV 0.98 V Voltage Charge 52.28 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.1 °C / 27.5 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-10 23:57
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.