Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.462 kW
07/15/2026 16:29 (2240 days) Production Consumption NET Usage
Now 0.532 kW 2.994 kW 2.462 kW
Today 25.061 kWh (1.517 kW) 19.283 kWh (1.167 kW) -5.778 kWh (-0.350 kW)
  - This Week 121.309 kWh (32.898 kWh/day) 124.137 kWh (33.665 kWh/day) 2.828 kWh (0.767 kWh/day)
  - This Month 391.863 kWh (26.679 kWh/day) 522.100 kWh (35.546 kWh/day) 130.237 kWh (8.867 kWh/day)
  - This Year 4.002 MWh (20.449 kWh/day) 3.809 MWh (19.464 kWh/day) -0.193 MWh (-0.985 kWh/day)
Yesterday 32.213 kWh (1.343 kW) 36.111 kWh (1.506 kW) 3.898 kWh (0.163 kW)
Last 7 Days 202.473 kWh (28.925 kWh/day) 238.883 kWh (34.126 kWh/day) 36.410 kWh (5.201 kWh/day)
Last 30 Days (06/15/2026) 756.029 kWh (25.201 kWh/day) 826.612 kWh (27.554 kWh/day) 70.583 kWh (2.353 kWh/day)
Last One Year 6.734 MWh (18.449 kWh/day) 7.661 MWh (20.989 kWh/day) 0.927 MWh (2.540 kWh/day)
Lifetime Since PTO 39.567 MWh (17.659 kW/day) 43.320 MWh (19.333 kW/day) 3.752 MWh (1.675 kW/day)
Lifetime Since Install 39.601 MWh 43.900 MWh 4.298 MWh
Voltage/Current 123.1 V / 2.2 A, 123.1 V / 2.2 A 122.7 V / 13.3 A, 123.4 V / 11.1 A 122.9 V / 11.1 A, 123.2 V / 8.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/17/2025 23:50 (23.7 hours) Number of Devices 18 set
Current Power 0.230 kW (0.013 kW/panel) Today Energy 15.996 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.152 0.722 1.043 10.213 0.000 kW
0.694 kWh
0.000 kW
4.165 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.135 0.689 0.995 9.758
03 - 202224****** IQ7+M [5] VCOP 0.000 0.150 0.722 1.032 10.141
04 - 202232****** IQ7+ [5] VCOP 0.000 0.148 0.721 1.036 10.244
05 - 202244****** IQ7+M [5] VCOP 0.000 0.141 0.641 0.979 9.548
06 - 202245****** IQ7+M [5] VCOP 0.000 0.141 0.670 1.014 9.788
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.119 0.555 0.997 9.789 0.000 kW
0.615 kWh
0.000 kW
3.077 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.133 0.626 1.018 10.360
09 - 202217****** IQ7+ [5] VCOP 0.000 0.130 0.629 1.015 10.292
10 - 202244****** IQ7+M [5] VCOP 0.000 0.132 0.633 1.014 10.320
11 - 202224****** IQ7+M [5] VCOP 0.000 0.131 0.635 1.020 10.458
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.143 0.779 0.883 8.103 0.000 kW
0.815 kWh
0.000 kW
3.258 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.153 0.808 0.922 8.247
14 - 202216****** IQ7+ [5] VCOP 0.000 0.148 0.834 0.951 8.549
15 - 202245****** IQ7+M [5] VCOP 0.000 0.152 0.838 0.957 8.566
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.077 kW
1.832 kWh
0.230 kW
5.495 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.495 5.542 38.528
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Charger History
Voltage PV 1.35 V Voltage Charge 51.41 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.3 °C / 27.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-17 23:58
voltage in/out power and energy internal/external temperature
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.