| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 3.359 kW | |||
|---|---|---|---|
| 07/15/2026 15:35 (2240 days) | Production | Consumption | NET Usage |
| Now | 1.026 kW | 4.385 kW | 3.359 kW |
| Today | 23.737 kWh (1.519 kW) | 16.700 kWh (1.069 kW) | -7.037 kWh (-0.450 kW) |
| - This Week | 119.985 kWh (32.873 kWh/day) | 121.554 kWh (33.303 kWh/day) | 1.569 kWh (0.430 kWh/day) |
| - This Month | 390.539 kWh (26.657 kWh/day) | 519.517 kWh (35.460 kWh/day) | 128.978 kWh (8.804 kWh/day) |
| - This Year | 4.000 MWh (20.447 kWh/day) | 3.806 MWh (19.455 kWh/day) | -0.194 MWh (-0.992 kWh/day) |
| Yesterday | 32.213 kWh (1.343 kW) | 36.111 kWh (1.506 kW) | 3.898 kWh (0.163 kW) |
| Last 7 Days | 204.291 kWh (29.184 kWh/day) | 237.343 kWh (33.906 kWh/day) | 33.052 kWh (4.722 kWh/day) |
| Last 30 Days (06/15/2026) | 757.937 kWh (25.265 kWh/day) | 824.776 kWh (27.493 kWh/day) | 66.839 kWh (2.228 kWh/day) |
| Last One Year | 6.733 MWh (18.447 kWh/day) | 7.661 MWh (20.988 kWh/day) | 0.927 MWh (2.541 kWh/day) |
| Lifetime Since PTO | 39.566 MWh (17.658 kW/day) | 43.317 MWh (19.332 kW/day) | 3.751 MWh (1.674 kW/day) |
| Lifetime Since Install | 39.600 MWh | 43.897 MWh | 4.297 MWh |
| Voltage/Current | 122.6 V / 4.2 A, 122.6 V / 4.2 A | 121.8 V / 24.7 A, 123.1 V / 11.2 A | 122.2 V / 20.4 A, 122.8 V / 7.0 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 11/19/2025 23:40 (17.5 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 10.651 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.235 | 0.646 | 0.915 | 4.806 | 0.000 kW 0.633 kWh |
0.000 kW 3.797 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.226 | 0.617 | 0.872 | 4.592 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.233 | 0.642 | 0.900 | 4.785 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.246 | 0.645 | 0.902 | 4.795 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.230 | 0.616 | 0.875 | 4.603 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.241 | 0.630 | 0.895 | 4.686 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.285 | 0.747 | 0.820 | 4.621 | 0.000 kW 0.756 kWh |
0.000 kW 3.778 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.288 | 0.759 | 0.974 | 5.150 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.285 | 0.756 | 1.064 | 5.464 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.291 | 0.756 | 1.048 | 5.456 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.293 | 0.759 | 0.971 | 5.254 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.094 | 0.319 | 0.473 | 2.790 | 0.000 kW 0.354 kWh |
0.000 kW 1.417 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.114 | 0.359 | 0.518 | 3.074 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.117 | 0.374 | 0.539 | 3.225 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.111 | 0.366 | 0.527 | 3.190 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.553 kWh |
0.000 kW 1.659 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.230 | 1.659 | 5.505 | 13.169 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.65 V | Voltage Charge | 52.43 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 27.8 °C / 24.5 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2025-11-19 23:58 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.61 V | Current/Power | -1.38 A (-72 W) |
| Remain Capacity/Energy | 211.9 Ah (10.8 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 35.7 % | State Of Health | 98.9 % |
| Run Time | 6d 9h 31m to empty | Report Date | 2025-11-19 23:54 |
|
|||
| Voltage | 52.57 V | Cell (MIN/MAX) | 3.280 V / 3.291 V (0.011 V) |
|---|---|---|---|
| Current/Power | -0.52 A (-27 W) | Runtime | 5d 17h 8m to empty |
| Remain Capacity/Energy | 70.6 Ah (3.6 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 35.7 % | State Of Health | 98.8 % |
| Temperature | 20.0 °C | Cycle | 227 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-11-19 23:54 |
| Voltage | 52.62 V | Cell (MIN/MAX) | 3.288 V / 3.289 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 71.6 Ah (3.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 72.0 % | State Of Health | 99.5 % |
| Temperature | 21.7 °C | Cycle | 160 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-11-19 23:59 |
| Voltage | 52.65 V | Cell (MIN/MAX) | 3.289 V / 3.291 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 70.6 Ah (3.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 71.0 % | State Of Health | 99.5 % |
| Temperature | 21.1 °C | Cycle | 165 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-11-19 23:59 |
| Voltage | 52.62 V | Cell (MIN/MAX) | 3.288 V / 3.289 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 71.2 Ah (3.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 71.6 % | State Of Health | 99.5 % |
| Temperature | 20.8 °C | Cycle | 167 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-11-19 23:58 |
| Voltage | 52.60 V | Cell (MIN/MAX) | 3.286 V / 3.288 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 70.5 Ah (3.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 71.1 % | State Of Health | 99.2 % |
| Temperature | 21.3 °C | Cycle | 166 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2025-11-19 23:54 |