Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.696 kW
07/18/2026 08:17 (2243 days) Production Consumption NET Usage
Now 1.097 kW 0.401 kW -0.696 kW
Today 2.813 kWh (0.339 kW) 3.877 kWh (0.467 kW) 1.064 kWh (0.128 kW)
  - This Week 185.560 kWh (29.243 kWh/day) 203.884 kWh (32.130 kWh/day) 18.324 kWh (2.888 kWh/day)
  - This Month 456.114 kWh (26.295 kWh/day) 601.847 kWh (34.696 kWh/day) 145.733 kWh (8.401 kWh/day)
  - This Year 4.066 MWh (20.499 kWh/day) 3.889 MWh (19.605 kWh/day) -0.177 MWh (-0.894 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.558 kWh (29.794 kWh/day) 231.338 kWh (33.048 kWh/day) 22.780 kWh (3.254 kWh/day)
Last 30 Days (06/18/2026) 753.710 kWh (25.124 kWh/day) 881.798 kWh (29.393 kWh/day) 128.088 kWh (4.270 kWh/day)
Last One Year 6.744 MWh (18.476 kWh/day) 7.640 MWh (20.931 kWh/day) 0.896 MWh (2.455 kWh/day)
Lifetime Since PTO 39.632 MWh (17.666 kW/day) 43.399 MWh (19.346 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.666 MWh 43.979 MWh 4.314 MWh
Voltage/Current 125.5 V / 4.4 A, 125.5 V / 4.4 A 125.4 V / 2.6 A, 125.6 V / 0.6 A 125.4 V / -1.8 A, 125.6 V / -3.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/16/2020 23:08 (12.0 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.298 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.482 1.632 8.971 0.000 kW
1.468 kWh
0.000 kW
8.807 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.212 1.468 1.614 8.890
03 - 202224****** IQ7+M [5] VCOP 0.000 0.216 1.492 1.637 9.051
04 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.482 1.627 8.976
05 - 202244****** IQ7+M [5] VCOP 0.000 0.214 1.438 1.594 8.728
06 - 202245****** IQ7+M [5] VCOP 0.000 0.215 1.444 1.600 8.766
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.225 1.512 1.686 9.049 0.000 kW
1.513 kWh
0.000 kW
7.566 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.226 1.456 1.641 8.837
09 - 202217****** IQ7+ [5] VCOP 0.000 0.226 1.530 1.695 9.047
10 - 202244****** IQ7+M [5] VCOP 0.000 0.228 1.542 1.704 9.234
11 - 202224****** IQ7+M [5] VCOP 0.000 0.226 1.527 1.690 9.151
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.177 1.235 1.313 7.593 0.000 kW
1.231 kWh
0.000 kW
4.925 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.179 1.223 1.297 7.501
14 - 202216****** IQ7+ [5] VCOP 0.000 0.179 1.242 1.320 7.665
15 - 202245****** IQ7+M [5] VCOP 0.000 0.176 1.225 1.300 7.547
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.80 A (10.358 kW)
Remain Capacity/Energy 578.4 Ah (29.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.9 % State Of Health 98.5 %
Run Time 4m to full Report Date 2020-09-16 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.