Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.007 kW
07/18/2026 06:19 (2243 days) Production Consumption NET Usage
Now 0.336 kW 0.329 kW -0.007 kW
Today 1.457 kWh (0.230 kW) 3.201 kWh (0.506 kW) 1.744 kWh (0.276 kW)
  - This Week 184.204 kWh (29.408 kWh/day) 203.208 kWh (32.442 kWh/day) 19.004 kWh (3.034 kWh/day)
  - This Month 454.758 kWh (26.341 kWh/day) 601.171 kWh (34.821 kWh/day) 146.413 kWh (8.481 kWh/day)
  - This Year 4.065 MWh (20.501 kWh/day) 3.888 MWh (19.610 kWh/day) -0.177 MWh (-0.891 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.486 kWh (29.784 kWh/day) 231.891 kWh (33.127 kWh/day) 23.405 kWh (3.344 kWh/day)
Last 30 Days (06/18/2026) 753.053 kWh (25.102 kWh/day) 881.462 kWh (29.382 kWh/day) 128.409 kWh (4.280 kWh/day)
Last One Year 6.743 MWh (18.475 kWh/day) 7.642 MWh (20.937 kWh/day) 0.899 MWh (2.462 kWh/day)
Lifetime Since PTO 39.630 MWh (17.666 kW/day) 43.399 MWh (19.346 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.979 MWh 4.315 MWh
Voltage/Current 126.1 V / 1.3 A, 126.1 V / 1.3 A 125.7 V / 2.1 A, 126.5 V / 0.5 A 125.9 V / 0.8 A, 126.3 V / -0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/06/2020 22:42 (11.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.979 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.648 1.102 8.378 0.000 kW
1.631 kWh
0.000 kW
9.787 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.627 1.087 8.270
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.649 1.101 8.377
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.635 1.092 8.305
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.618 1.064 8.181
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.609 1.059 8.128
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.766 1.030 8.554 0.000 kW
1.765 kWh
0.000 kW
8.825 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.649 0.893 7.989
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.787 1.078 8.678
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.818 1.084 8.769
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.804 1.066 8.700
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.222 1.092 0.982 6.300 0.000 kW
1.092 kWh
0.000 kW
4.367 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.223 1.084 0.972 6.230
14 - 202216****** IQ7+ [5] VCOP 0.000 0.223 1.106 0.977 6.329
15 - 202245****** IQ7+M [5] VCOP 0.000 0.217 1.086 0.963 6.210
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.05 A (9.807 kW)
Remain Capacity/Energy 563.7 Ah (28.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 95.4 % State Of Health 98.5 %
Run Time 9m to full Report Date 2020-10-06 23:24
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.506 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 187.9 Ah (9.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 95.4 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-06 23:24
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.500 V 3.494 V 3.502 V 3.501 V 3.497 V 3.497 V 3.504 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.502 V 3.503 V 3.500 V 3.505 V 3.506 V 3.505 V 3.506 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -