Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.282 kW
07/18/2026 06:47 (2243 days) Production Consumption NET Usage
Now 0.608 kW 0.326 kW -0.282 kW
Today 1.670 kWh (0.246 kW) 3.346 kWh (0.492 kW) 1.676 kWh (0.247 kW)
  - This Week 184.417 kWh (29.352 kWh/day) 203.353 kWh (32.365 kWh/day) 18.936 kWh (3.014 kWh/day)
  - This Month 454.971 kWh (26.324 kWh/day) 601.316 kWh (34.791 kWh/day) 146.345 kWh (8.467 kWh/day)
  - This Year 4.065 MWh (20.500 kWh/day) 3.888 MWh (19.609 kWh/day) -0.177 MWh (-0.891 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.501 kWh (29.786 kWh/day) 231.772 kWh (33.110 kWh/day) 23.271 kWh (3.324 kWh/day)
Last 30 Days (06/18/2026) 753.241 kWh (25.108 kWh/day) 881.587 kWh (29.386 kWh/day) 128.346 kWh (4.278 kWh/day)
Last One Year 6.743 MWh (18.475 kWh/day) 7.641 MWh (20.934 kWh/day) 0.897 MWh (2.459 kWh/day)
Lifetime Since PTO 39.630 MWh (17.666 kW/day) 43.399 MWh (19.346 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.979 MWh 4.314 MWh
Voltage/Current 125.8 V / 2.4 A, 125.8 V / 2.4 A 125.7 V / 2.2 A, 125.9 V / 0.4 A 125.8 V / -0.2 A, 125.9 V / -2.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/10/2020 22:34 (10.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.433 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.200 0.948 1.559 10.071 0.000 kW
0.938 kWh
0.000 kW
5.626 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.197 0.936 1.535 9.936
03 - 202224****** IQ7+M [5] VCOP 0.000 0.201 0.950 1.554 10.053
04 - 202232****** IQ7+ [5] VCOP 0.000 0.201 0.940 1.542 9.971
05 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.926 1.522 9.825
06 - 202245****** IQ7+M [5] VCOP 0.000 0.199 0.926 1.512 9.760
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.218 0.915 1.708 10.438 0.000 kW
0.931 kWh
0.000 kW
4.657 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.218 0.830 1.643 9.596
09 - 202217****** IQ7+ [5] VCOP 0.000 0.220 0.976 1.728 10.624
10 - 202244****** IQ7+M [5] VCOP 0.000 0.221 0.979 1.755 10.791
11 - 202224****** IQ7+M [5] VCOP 0.000 0.219 0.957 1.733 10.681
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.142 0.790 0.986 7.286 0.000 kW
0.787 kWh
0.000 kW
3.149 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.143 0.789 0.987 7.233
14 - 202216****** IQ7+ [5] VCOP 0.000 0.142 0.792 1.007 7.337
15 - 202245****** IQ7+M [5] VCOP 0.000 0.140 0.779 0.988 7.203
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.05 A (9.808 kW)
Remain Capacity/Energy 560.7 Ah (28.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 94.9 % State Of Health 98.5 %
Run Time 10m to full Report Date 2020-10-10 23:37
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.494 V / 3.504 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 186.9 Ah (9.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 94.9 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-10 23:37
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.501 V 3.495 V 3.500 V 3.503 V 3.500 V 3.500 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.502 V 3.504 V 3.503 V 3.502 V 3.504 V 3.504 V 3.503 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -