Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.047 kW
07/18/2026 05:21 (2243 days) Production Consumption NET Usage
Now 0.226 kW 0.273 kW 0.047 kW
Today 1.209 kWh (0.226 kW) 2.894 kWh (0.540 kW) 1.685 kWh (0.315 kW)
  - This Week 183.956 kWh (29.560 kWh/day) 202.901 kWh (32.604 kWh/day) 18.945 kWh (3.044 kWh/day)
  - This Month 454.510 kWh (26.388 kWh/day) 600.864 kWh (34.885 kWh/day) 146.354 kWh (8.497 kWh/day)
  - This Year 4.064 MWh (20.504 kWh/day) 3.888 MWh (19.612 kWh/day) -0.177 MWh (-0.891 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.483 kWh (29.783 kWh/day) 231.957 kWh (33.137 kWh/day) 23.474 kWh (3.353 kWh/day)
Last 30 Days (06/18/2026) 752.816 kWh (25.094 kWh/day) 881.139 kWh (29.371 kWh/day) 128.323 kWh (4.277 kWh/day)
Last One Year 6.743 MWh (18.474 kWh/day) 7.642 MWh (20.938 kWh/day) 0.899 MWh (2.464 kWh/day)
Lifetime Since PTO 39.630 MWh (17.667 kW/day) 43.398 MWh (19.346 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.978 MWh 4.314 MWh
Voltage/Current 125.9 V / 0.9 A, 125.9 V / 0.9 A 125.4 V / 1.6 A, 126.2 V / 0.5 A 125.7 V / 0.7 A, 126.1 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/02/2020 23:20 (10.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.499 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.283 1.241 0.284 3.156 0.000 kW
1.212 kWh
0.000 kW
7.275 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.277 1.188 0.280 3.047
03 - 202224****** IQ7+M [0] ---- 0.000 0.285 1.186 0.286 3.144
04 - 202232****** IQ7+ [0] ---- 0.000 0.286 1.182 0.281 3.098
05 - 202244****** IQ7+M [0] ---- 0.000 0.282 1.221 0.278 3.099
06 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.256 0.280 3.144
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.300 1.480 0.266 3.301 0.000 kW
1.503 kWh
0.000 kW
7.517 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.299 1.415 0.252 3.128
09 - 202217****** IQ7+ [0] ---- 0.000 0.299 1.555 0.270 3.437
10 - 202244****** IQ7+M [0] ---- 0.000 0.302 1.555 0.271 3.443
11 - 202224****** IQ7+M [0] ---- 0.000 0.301 1.513 0.267 3.326
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.199 0.631 0.260 2.288 0.000 kW
0.677 kWh
0.000 kW
2.708 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.203 0.695 0.262 2.358
14 - 202216****** IQ7+ [0] ---- 0.000 0.202 0.697 0.265 2.409
15 - 202245****** IQ7+M [0] ---- 0.000 0.193 0.685 0.261 2.354
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.02 V Current/Power 178.15 A (10.158 kW)
Remain Capacity/Energy 587.4 Ah (30.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.4 % State Of Health 98.5 %
Run Time 1m to full Report Date 2020-11-02 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.02 V Cell (MIN/MAX) 3.551 V / 3.568 V (0.017 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 195.8 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.4 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-02 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.563 V 3.561 V 3.563 V 3.558 V 3.551 V 3.565 V 3.564 V 3.565 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.564 V 3.566 V 3.566 V 3.565 V 3.564 V 3.566 V 3.568 V 3.568 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -