Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.117 kW
07/18/2026 04:36 (2243 days) Production Consumption NET Usage
Now 0.225 kW 0.342 kW 0.117 kW
Today 1.043 kWh (0.226 kW) 2.636 kWh (0.571 kW) 1.593 kWh (0.345 kW)
  - This Week 183.790 kWh (29.680 kWh/day) 202.643 kWh (32.725 kWh/day) 18.853 kWh (3.045 kWh/day)
  - This Month 454.344 kWh (26.426 kWh/day) 600.606 kWh (34.933 kWh/day) 146.262 kWh (8.507 kWh/day)
  - This Year 4.064 MWh (20.506 kWh/day) 3.887 MWh (19.614 kWh/day) -0.177 MWh (-0.892 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.485 kWh (29.784 kWh/day) 232.255 kWh (33.179 kWh/day) 23.770 kWh (3.396 kWh/day)
Last 30 Days (06/18/2026) 752.650 kWh (25.088 kWh/day) 880.902 kWh (29.363 kWh/day) 128.252 kWh (4.275 kWh/day)
Last One Year 6.743 MWh (18.474 kWh/day) 7.642 MWh (20.938 kWh/day) 0.899 MWh (2.464 kWh/day)
Lifetime Since PTO 39.630 MWh (17.667 kW/day) 43.398 MWh (19.347 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.978 MWh 4.314 MWh
Voltage/Current 125.8 V / 0.9 A, 125.8 V / 0.9 A 125.4 V / 2.2 A, 126.0 V / 0.5 A 125.6 V / 1.3 A, 125.9 V / -0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/17/2020 21:53 (9.3 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.747 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.151 0.398 1.152 4.074 0.000 kW
0.392 kWh
0.000 kW
2.355 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.149 0.392 1.134 4.086
03 - 202224****** IQ7+M [0] ---- 0.000 0.153 0.399 1.127 4.109
04 - 202232****** IQ7+ [0] ---- 0.000 0.148 0.388 1.082 3.983
05 - 202244****** IQ7+M [0] ---- 0.000 0.150 0.388 1.165 4.009
06 - 202245****** IQ7+M [0] ---- 0.000 0.150 0.389 1.137 3.861
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.170 0.388 1.351 4.588 0.000 kW
0.392 kWh
0.000 kW
1.961 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.170 0.386 1.197 4.056
09 - 202217****** IQ7+ [0] ---- 0.000 0.172 0.398 1.498 5.017
10 - 202244****** IQ7+M [0] ---- 0.000 0.171 0.399 1.476 4.971
11 - 202224****** IQ7+M [0] ---- 0.000 0.170 0.390 1.380 4.695
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.095 0.355 0.500 2.356 0.000 kW
0.358 kWh
0.000 kW
1.431 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.095 0.357 0.573 2.537
14 - 202216****** IQ7+ [0] ---- 0.000 0.097 0.364 0.565 2.459
15 - 202245****** IQ7+M [0] ---- 0.000 0.096 0.355 0.549 2.456
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.48 V Current/Power 163.88 A (8.600 kW)
Remain Capacity/Energy 352.8 Ah (18.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 59.7 % State Of Health 98.5 %
Run Time 1h 27m to full Report Date 2020-11-17 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.