Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.190 kW
07/18/2026 03:56 (2243 days) Production Consumption NET Usage
Now 0.225 kW 0.415 kW 0.190 kW
Today 0.888 kWh (0.226 kW) 2.358 kWh (0.599 kW) 1.470 kWh (0.373 kW)
  - This Week 183.635 kWh (29.792 kWh/day) 202.365 kWh (32.830 kWh/day) 18.730 kWh (3.039 kWh/day)
  - This Month 454.189 kWh (26.461 kWh/day) 600.328 kWh (34.975 kWh/day) 146.139 kWh (8.514 kWh/day)
  - This Year 4.064 MWh (20.508 kWh/day) 3.887 MWh (19.616 kWh/day) -0.177 MWh (-0.893 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.478 kWh (29.783 kWh/day) 232.219 kWh (33.174 kWh/day) 23.741 kWh (3.392 kWh/day)
Last 30 Days (06/18/2026) 752.495 kWh (25.083 kWh/day) 880.629 kWh (29.354 kWh/day) 128.134 kWh (4.271 kWh/day)
Last One Year 6.743 MWh (18.473 kWh/day) 7.643 MWh (20.938 kWh/day) 0.900 MWh (2.465 kWh/day)
Lifetime Since PTO 39.630 MWh (17.667 kW/day) 43.398 MWh (19.347 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.978 MWh 4.314 MWh
Voltage/Current 125.5 V / 0.9 A, 125.5 V / 0.9 A 125.2 V / 2.8 A, 125.7 V / 0.5 A 125.4 V / 1.9 A, 125.6 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/04/2020 22:12 (8.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.991 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.105 0.207 0.919 3.874 0.000 kW
0.204 kWh
0.000 kW
1.227 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.103 0.203 0.888 3.739
03 - 202224****** IQ7+M [0] ---- 0.000 0.099 0.208 0.869 3.672
04 - 202232****** IQ7+ [0] ---- 0.000 0.095 0.204 0.814 3.468
05 - 202244****** IQ7+M [0] ---- 0.000 0.104 0.202 0.974 4.065
06 - 202245****** IQ7+M [0] ---- 0.000 0.103 0.203 0.970 4.060
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.107 0.189 1.172 4.564 0.000 kW
0.190 kWh
0.000 kW
0.951 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.107 0.188 1.031 3.856
09 - 202217****** IQ7+ [0] ---- 0.000 0.114 0.191 1.268 4.924
10 - 202244****** IQ7+M [0] ---- 0.000 0.109 0.193 1.260 4.909
11 - 202224****** IQ7+M [0] ---- 0.000 0.108 0.190 1.144 4.476
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.085 0.202 0.355 2.185 0.000 kW
0.203 kWh
0.000 kW
0.814 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.085 0.203 0.416 2.350
14 - 202216****** IQ7+ [0] ---- 0.000 0.085 0.206 0.407 2.343
15 - 202245****** IQ7+M [0] ---- 0.000 0.084 0.203 0.396 2.284
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.20 V Current/Power 166.16 A (8.840 kW)
Remain Capacity/Energy 507.3 Ah (26.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 85.8 % State Of Health 98.5 %
Run Time 30m to full Report Date 2020-12-04 23:29
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.20 V Cell (MIN/MAX) 3.319 V / 3.329 V (0.010 V)
Current/Power -0.57 A (-30 W) Runtime 12d 9h 12m to empty
Remain Capacity/Energy 169.1 Ah (8.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 85.8 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-12-04 23:29
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.321 V 3.322 V 3.323 V 3.323 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.326 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V 3.329 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -