Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.139 kW
07/18/2026 04:05 (2243 days) Production Consumption NET Usage
Now 0.225 kW 0.364 kW 0.139 kW
Today 0.925 kWh (0.226 kW) 2.426 kWh (0.592 kW) 1.501 kWh (0.366 kW)
  - This Week 183.672 kWh (29.765 kWh/day) 202.433 kWh (32.806 kWh/day) 18.761 kWh (3.040 kWh/day)
  - This Month 454.226 kWh (26.452 kWh/day) 600.396 kWh (34.965 kWh/day) 146.170 kWh (8.512 kWh/day)
  - This Year 4.064 MWh (20.508 kWh/day) 3.887 MWh (19.615 kWh/day) -0.177 MWh (-0.893 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.479 kWh (29.783 kWh/day) 232.225 kWh (33.175 kWh/day) 23.746 kWh (3.392 kWh/day)
Last 30 Days (06/18/2026) 752.532 kWh (25.084 kWh/day) 880.705 kWh (29.357 kWh/day) 128.173 kWh (4.272 kWh/day)
Last One Year 6.743 MWh (18.473 kWh/day) 7.643 MWh (20.938 kWh/day) 0.900 MWh (2.465 kWh/day)
Lifetime Since PTO 39.630 MWh (17.667 kW/day) 43.398 MWh (19.347 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.978 MWh 4.314 MWh
Voltage/Current 125.7 V / 0.9 A, 125.7 V / 0.9 A 125.4 V / 2.4 A, 125.9 V / 0.5 A 125.5 V / 1.5 A, 125.8 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/08/2020 21:45 (8.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.505 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.201 0.369 0.773 4.017 0.000 kW
0.371 kWh
0.000 kW
2.225 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.200 0.365 0.746 3.901
03 - 202224****** IQ7+M [0] ---- 0.000 0.198 0.377 0.725 3.848
04 - 202232****** IQ7+ [0] ---- 0.000 0.199 0.373 0.688 3.652
05 - 202244****** IQ7+M [0] ---- 0.000 0.203 0.376 0.793 4.174
06 - 202245****** IQ7+M [0] ---- 0.000 0.201 0.365 0.790 4.164
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.282 0.434 0.995 4.927 0.000 kW
0.449 kWh
0.000 kW
2.246 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.284 0.433 0.937 4.433
09 - 202217****** IQ7+ [0] ---- 0.000 0.279 0.463 1.047 5.252
10 - 202244****** IQ7+M [0] ---- 0.000 0.284 0.461 1.046 5.226
11 - 202224****** IQ7+M [0] ---- 0.000 0.281 0.454 1.011 4.900
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.072 0.256 0.346 2.079 0.000 kW
0.259 kWh
0.000 kW
1.034 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.073 0.259 0.386 2.277
14 - 202216****** IQ7+ [0] ---- 0.000 0.074 0.262 0.384 2.270
15 - 202245****** IQ7+M [0] ---- 0.000 0.072 0.257 0.376 2.214
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.70 V Current/Power 164.31 A (8.659 kW)
Remain Capacity/Energy 371.7 Ah (19.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Run Time 1h 20m to full Report Date 2020-12-08 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.70 V Cell (MIN/MAX) 3.284 V / 3.307 V (0.023 V)
Current/Power -0.57 A (-30 W) Runtime 9d 0h 36m to empty
Remain Capacity/Energy 123.9 Ah (6.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-08 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.285 V 3.284 V 3.285 V 3.285 V 3.291 V 3.286 V 3.289 V 3.287 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.298 V 3.289 V 3.303 V 3.291 V 3.303 V 3.305 V 3.305 V 3.307 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -