Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.165 kW
07/18/2026 03:57 (2243 days) Production Consumption NET Usage
Now 0.226 kW 0.391 kW 0.165 kW
Today 0.895 kWh (0.226 kW) 2.368 kWh (0.598 kW) 1.473 kWh (0.372 kW)
  - This Week 183.642 kWh (29.788 kWh/day) 202.375 kWh (32.826 kWh/day) 18.733 kWh (3.039 kWh/day)
  - This Month 454.196 kWh (26.459 kWh/day) 600.338 kWh (34.973 kWh/day) 146.142 kWh (8.514 kWh/day)
  - This Year 4.064 MWh (20.508 kWh/day) 3.887 MWh (19.616 kWh/day) -0.177 MWh (-0.893 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.483 kWh (29.783 kWh/day) 232.226 kWh (33.175 kWh/day) 23.743 kWh (3.392 kWh/day)
Last 30 Days (06/18/2026) 752.502 kWh (25.083 kWh/day) 880.641 kWh (29.355 kWh/day) 128.139 kWh (4.271 kWh/day)
Last One Year 6.743 MWh (18.473 kWh/day) 7.643 MWh (20.938 kWh/day) 0.900 MWh (2.465 kWh/day)
Lifetime Since PTO 39.630 MWh (17.667 kW/day) 43.398 MWh (19.347 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.664 MWh 43.978 MWh 4.314 MWh
Voltage/Current 125.5 V / 0.9 A, 125.5 V / 0.9 A 125.1 V / 2.4 A, 125.7 V / 0.7 A 125.3 V / 1.5 A, 125.6 V / -0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/09/2020 21:58 (8.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.535 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.127 0.325 0.369 3.935 0.000 kW
0.323 kWh
0.000 kW
1.940 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.139 0.315 0.365 3.819
03 - 202224****** IQ7+M [0] ---- 0.000 0.142 0.326 0.377 3.782
04 - 202232****** IQ7+ [0] ---- 0.000 0.115 0.308 0.373 3.610
05 - 202244****** IQ7+M [0] ---- 0.000 0.162 0.332 0.376 4.090
06 - 202245****** IQ7+M [0] ---- 0.000 0.171 0.334 0.365 4.064
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.200 0.342 0.434 4.873 0.000 kW
0.288 kWh
0.000 kW
1.441 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.061 0.052 0.433 4.437
09 - 202217****** IQ7+ [0] ---- 0.000 0.207 0.354 0.463 5.206
10 - 202244****** IQ7+M [0] ---- 0.000 0.200 0.351 0.461 5.177
11 - 202224****** IQ7+M [0] ---- 0.000 0.201 0.343 0.454 4.870
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.101 0.284 0.256 2.013 0.000 kW
0.288 kWh
0.000 kW
1.154 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.105 0.290 0.259 2.203
14 - 202216****** IQ7+ [0] ---- 0.000 0.102 0.294 0.262 2.197
15 - 202245****** IQ7+M [0] ---- 0.000 0.103 0.285 0.257 2.144
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.605 kW)
Remain Capacity/Energy 334.2 Ah (17.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Run Time 1h 33m to full Report Date 2020-12-09 21:48
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.49 V Cell (MIN/MAX) 3.276 V / 3.285 V (0.009 V)
Current/Power -0.55 A (-28 W) Runtime 8d 10h 32m to empty
Remain Capacity/Energy 111.4 Ah (5.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-09 21:48
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.276 V 3.276 V 3.277 V 3.278 V 3.279 V 3.278 V 3.280 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.283 V 3.282 V 3.283 V 3.284 V 3.285 V 3.285 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -