Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.113 kW
07/18/2026 02:57 (2243 days) Production Consumption NET Usage
Now 0.226 kW 0.339 kW 0.113 kW
Today 0.668 kWh (0.226 kW) 1.836 kWh (0.621 kW) 1.168 kWh (0.395 kW)
  - This Week 183.415 kWh (29.954 kWh/day) 201.843 kWh (32.964 kWh/day) 18.428 kWh (3.010 kWh/day)
  - This Month 453.969 kWh (26.511 kWh/day) 599.806 kWh (35.027 kWh/day) 145.837 kWh (8.517 kWh/day)
  - This Year 4.064 MWh (20.511 kWh/day) 3.887 MWh (19.617 kWh/day) -0.177 MWh (-0.894 kWh/day)
Yesterday 36.720 kWh (1.530 kW) 31.066 kWh (1.294 kW) -5.654 kWh (-0.236 kW)
Last 7 Days 208.482 kWh (29.783 kWh/day) 232.275 kWh (33.182 kWh/day) 23.793 kWh (3.399 kWh/day)
Last 30 Days (06/18/2026) 752.275 kWh (25.076 kWh/day) 880.371 kWh (29.346 kWh/day) 128.096 kWh (4.270 kWh/day)
Last One Year 6.743 MWh (18.473 kWh/day) 7.643 MWh (20.939 kWh/day) 0.900 MWh (2.466 kWh/day)
Lifetime Since PTO 39.629 MWh (17.667 kW/day) 43.397 MWh (19.347 kW/day) 3.768 MWh (1.680 kW/day)
Lifetime Since Install 39.663 MWh 43.977 MWh 4.314 MWh
Voltage/Current 125.1 V / 0.9 A, 125.1 V / 0.9 A 125.0 V / 2.2 A, 125.3 V / 0.5 A 125.1 V / 1.3 A, 125.2 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/30/2020 21:47 (8.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.649 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.173 0.534 0.762 4.379 0.000 kW
0.505 kWh
0.000 kW
3.031 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.164 0.480 0.695 4.047
03 - 202224****** IQ7+M [0] ---- 0.000 0.165 0.491 0.678 4.070
04 - 202232****** IQ7+ [0] ---- 0.000 0.170 0.492 0.650 4.003
05 - 202244****** IQ7+M [0] ---- 0.000 0.162 0.503 0.777 4.367
06 - 202245****** IQ7+M [0] ---- 0.000 0.169 0.532 0.818 4.541
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.213 0.621 1.044 5.694 0.000 kW
0.615 kWh
0.000 kW
3.073 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.206 0.565 0.879 5.055
09 - 202217****** IQ7+ [0] ---- 0.000 0.214 0.633 1.115 6.082
10 - 202244****** IQ7+M [0] ---- 0.000 0.215 0.638 1.099 6.021
11 - 202224****** IQ7+M [0] ---- 0.000 0.213 0.616 1.022 5.590
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.105 0.375 0.338 1.860 0.000 kW
0.386 kWh
0.000 kW
1.544 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.108 0.389 0.385 2.138
14 - 202216****** IQ7+ [0] ---- 0.000 0.107 0.394 0.382 2.125
15 - 202245****** IQ7+M [0] ---- 0.000 0.104 0.387 0.372 2.060
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.27 V Current/Power 166.36 A (8.861 kW)
Remain Capacity/Energy 515.1 Ah (26.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 87.2 % State Of Health 98.5 %
Run Time 27m to full Report Date 2020-12-30 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.27 V Cell (MIN/MAX) 3.323 V / 3.333 V (0.010 V)
Current/Power -0.25 A (-13 W) Runtime 28d 3h 59m to empty
Remain Capacity/Energy 171.7 Ah (8.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 87.2 % State Of Health 98.5 %
Temperature 18.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2020-12-30 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.325 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.329 V 3.330 V 3.330 V 3.331 V 3.332 V 3.333 V 3.333 V 3.333 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -