| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 1.489 kW | |||
|---|---|---|---|
| 07/17/2026 14:08 (2242 days) | Production | Consumption | NET Usage |
| Now | 4.413 kW | 2.924 kW | -1.489 kW |
| Today | 21.029 kWh (1.486 kW) | 10.441 kWh (0.738 kW) | -10.588 kWh (-0.748 kW) |
| - This Week | 167.056 kWh (29.888 kWh/day) | 179.382 kWh (32.094 kWh/day) | 12.326 kWh (2.205 kWh/day) |
| - This Month | 437.610 kWh (26.378 kWh/day) | 577.345 kWh (34.801 kWh/day) | 139.735 kWh (8.423 kWh/day) |
| - This Year | 4.047 MWh (20.484 kWh/day) | 3.864 MWh (19.556 kWh/day) | -0.183 MWh (-0.928 kWh/day) |
| Yesterday | 22.649 kWh (0.943 kW) | 31.495 kWh (1.312 kW) | 8.846 kWh (0.368 kW) |
| Last 7 Days | 203.153 kWh (29.022 kWh/day) | 231.267 kWh (33.038 kWh/day) | 28.114 kWh (4.016 kWh/day) |
| Last 30 Days (06/17/2026) | 744.903 kWh (24.830 kWh/day) | 870.220 kWh (29.007 kWh/day) | 125.317 kWh (4.177 kWh/day) |
| Last One Year | 6.736 MWh (18.456 kWh/day) | 7.647 MWh (20.950 kWh/day) | 0.910 MWh (2.494 kWh/day) |
| Lifetime Since PTO | 39.613 MWh (17.664 kW/day) | 43.375 MWh (19.341 kW/day) | 3.762 MWh (1.677 kW/day) |
| Lifetime Since Install | 39.647 MWh | 43.955 MWh | 4.308 MWh |
| Voltage/Current | 124.3 V / 17.7 A, 124.3 V / 17.7 A | 124.1 V / 14.3 A, 124.6 V / 9.2 A | 124.2 V / -3.5 A, 124.5 V / -8.5 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 12/22/2021 22:49 (8.6 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 11.643 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.216 | 0.850 | 0.537 | 4.356 | 0.000 kW 0.834 kWh |
0.000 kW 5.004 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.209 | 0.814 | 0.505 | 4.106 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.210 | 0.856 | 0.538 | 4.375 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.208 | 0.821 | 0.527 | 4.258 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.212 | 0.847 | 0.511 | 4.251 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.210 | 0.816 | 0.507 | 4.154 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.276 | 1.071 | 0.576 | 5.139 | 0.000 kW 1.054 kWh |
0.000 kW 5.269 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.271 | 0.971 | 0.539 | 4.607 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.274 | 1.095 | 0.594 | 5.336 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.272 | 1.077 | 0.590 | 5.152 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.274 | 1.056 | 0.565 | 5.006 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.090 | 0.300 | 0.376 | 2.118 | 0.000 kW 0.342 kWh |
0.000 kW 1.369 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.092 | 0.358 | 0.380 | 2.310 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.092 | 0.360 | 0.388 | 2.335 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.091 | 0.351 | 0.380 | 2.288 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.32 V | Current/Power | -1.32 A (-70 W) |
| Remain Capacity/Energy | 396.6 Ah (20.3 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 66.1 % | State Of Health | 100.0 % |
| Run Time | 12d 12h 27m to empty | Report Date | 2021-12-22 23:52 |
|
|||
| Voltage | 53.36 V | Cell (MIN/MAX) | 3.297 V / 3.341 V (0.044 V) |
|---|---|---|---|
| Current/Power | -0.46 A (-24 W) | Runtime | 11d 22h 46m to empty |
| Remain Capacity/Energy | 132.2 Ah (6.8 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 66.1 % | State Of Health | 100.0 % |
| Temperature | 20.0 °C | Cycle | 50 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-12-22 23:52 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.330 V / 3.332 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 22.3 °C | Cycle | 8 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-12-22 23:56 |
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.332 V / 3.334 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 20.7 °C | Cycle | 8 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-12-22 23:58 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.330 V / 3.332 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 19.8 °C | Cycle | 8 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-12-22 23:56 |
| Voltage | 53.31 V | Cell (MIN/MAX) | 3.331 V / 3.332 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.2 Ah (5.1 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.7 % |
| Temperature | 21.6 °C | Cycle | 8 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-12-22 23:58 |