Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.401 kW
07/17/2026 07:16 (2242 days) Production Consumption NET Usage
Now 0.780 kW 0.379 kW -0.401 kW
Today 2.023 kWh (0.278 kW) 3.419 kWh (0.469 kW) 1.396 kWh (0.192 kW)
  - This Week 148.050 kWh (27.916 kWh/day) 172.360 kWh (32.500 kWh/day) 24.310 kWh (4.584 kWh/day)
  - This Month 418.604 kWh (25.675 kWh/day) 570.323 kWh (34.980 kWh/day) 151.719 kWh (9.306 kWh/day)
  - This Year 4.028 MWh (20.417 kWh/day) 3.857 MWh (19.549 kWh/day) -0.171 MWh (-0.868 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.683 kWh (28.383 kWh/day) 237.791 kWh (33.970 kWh/day) 39.108 kWh (5.587 kWh/day)
Last 30 Days (06/17/2026) 742.650 kWh (24.755 kWh/day) 865.585 kWh (28.853 kWh/day) 122.935 kWh (4.098 kWh/day)
Last One Year 6.730 MWh (18.438 kWh/day) 7.645 MWh (20.946 kWh/day) 0.915 MWh (2.508 kWh/day)
Lifetime Since PTO 39.594 MWh (17.658 kW/day) 43.368 MWh (19.341 kW/day) 3.774 MWh (1.683 kW/day)
Lifetime Since Install 39.628 MWh 43.948 MWh 4.320 MWh
Voltage/Current 124.5 V / 3.1 A, 124.5 V / 3.1 A 124.3 V / 2.7 A, 124.7 V / 0.4 A 124.4 V / -0.5 A, 124.6 V / -2.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/23/2022 22:53 (14.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.157 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.282 2.221 1.992 11.055 0.000 kW
2.107 kWh
0.000 kW
12.640 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.273 2.080 1.881 10.404
03 - 202224****** IQ7+M [5] VCOP 0.000 0.278 2.143 1.928 10.748
04 - 202232****** IQ7+ [5] VCOP 0.000 0.278 2.152 1.917 10.677
05 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.939 1.820 10.007
06 - 202245****** IQ7+M [0] VCOP 0.000 0.271 2.106 1.912 10.541
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 2.049 1.822 10.033 0.000 kW
2.037 kWh
0.000 kW
10.184 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 1.989 1.833 9.858
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 2.009 1.814 9.890
10 - 202244****** IQ7+M [5] VCOP 0.000 0.278 2.063 1.830 10.093
11 - 202224****** IQ7+M [5] VCOP 0.000 0.279 2.073 1.849 10.153
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.251 2.128 1.975 10.858 0.000 kW
2.083 kWh
0.000 kW
8.334 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.247 2.016 1.906 10.545
14 - 202216****** IQ7+ [5] VCOP 0.000 0.251 2.122 1.973 10.891
15 - 202245****** IQ7+M [5] VCOP 0.000 0.247 2.068 1.929 10.714
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Battery History
Voltage 53.26 V Current/Power -1.23 A (-65 W)
Remain Capacity/Energy 522.3 Ah (26.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.1 % State Of Health 100.0 %
Run Time 17d 16h 38m to empty Report Date 2022-07-23 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.