Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.137 kW
07/17/2026 03:27 (2242 days) Production Consumption NET Usage
Now 0.226 kW 0.363 kW 0.137 kW
Today 0.783 kWh (0.226 kW) 1.803 kWh (0.520 kW) 1.020 kWh (0.294 kW)
  - This Week 146.810 kWh (28.540 kWh/day) 170.744 kWh (33.192 kWh/day) 23.934 kWh (4.653 kWh/day)
  - This Month 417.364 kWh (25.851 kWh/day) 568.707 kWh (35.225 kWh/day) 151.343 kWh (9.374 kWh/day)
  - This Year 4.027 MWh (20.428 kWh/day) 3.855 MWh (19.557 kWh/day) -0.172 MWh (-0.871 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.714 kWh (28.388 kWh/day) 238.455 kWh (34.065 kWh/day) 39.741 kWh (5.677 kWh/day)
Last 30 Days (06/17/2026) 741.927 kWh (24.731 kWh/day) 864.142 kWh (28.805 kWh/day) 122.215 kWh (4.074 kWh/day)
Last One Year 6.729 MWh (18.435 kWh/day) 7.647 MWh (20.950 kWh/day) 0.918 MWh (2.515 kWh/day)
Lifetime Since PTO 39.593 MWh (17.658 kW/day) 43.366 MWh (19.341 kW/day) 3.773 MWh (1.683 kW/day)
Lifetime Since Install 39.627 MWh 43.946 MWh 4.319 MWh
Voltage/Current 125.9 V / 0.9 A, 125.9 V / 0.9 A 125.6 V / 2.3 A, 126.2 V / 0.5 A 125.8 V / 1.4 A, 126.1 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/20/2022 22:47 (9.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.368 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.241 1.140 1.137 6.066 0.000 kW
1.115 kWh
0.000 kW
6.687 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.236 1.089 1.093 5.813
03 - 202224****** IQ7+M [0] ---- 0.000 0.240 1.117 1.134 6.066
04 - 202232****** IQ7+ [0] ---- 0.000 0.237 1.114 1.110 5.939
05 - 202244****** IQ7+M [0] ---- 0.000 0.237 1.133 1.133 5.982
06 - 202245****** IQ7+M [0] ---- 0.000 0.234 1.094 1.091 5.804
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.176 1.168 6.226 0.000 kW
1.328 kWh
0.000 kW
6.640 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.309 1.330 6.835
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.427 1.420 7.200
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.405 1.403 7.139
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.323 1.320 6.858
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.124 0.463 0.467 3.178 0.000 kW
0.510 kWh
0.000 kW
2.041 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.133 0.529 0.539 3.451
14 - 202216****** IQ7+ [0] ---- 0.000 0.135 0.534 0.543 3.482
15 - 202245****** IQ7+M [0] ---- 0.000 0.132 0.516 0.517 3.387
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Battery History
Voltage 53.29 V Current/Power -1.65 A (-87 W)
Remain Capacity/Energy 456.3 Ah (23.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 76.1 % State Of Health 100.0 %
Run Time 11d 12h 33m to empty Report Date 2022-11-20 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.