Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.015 kW
07/17/2026 02:19 (2242 days) Production Consumption NET Usage
Now 0.226 kW 0.241 kW 0.015 kW
Today 0.529 kWh (0.226 kW) 1.369 kWh (0.585 kW) 0.840 kWh (0.359 kW)
  - This Week 146.556 kWh (28.752 kWh/day) 170.310 kWh (33.412 kWh/day) 23.754 kWh (4.660 kWh/day)
  - This Month 417.110 kWh (25.911 kWh/day) 568.273 kWh (35.301 kWh/day) 151.163 kWh (9.390 kWh/day)
  - This Year 4.027 MWh (20.431 kWh/day) 3.855 MWh (19.559 kWh/day) -0.172 MWh (-0.872 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.710 kWh (28.387 kWh/day) 238.833 kWh (34.119 kWh/day) 40.123 kWh (5.732 kWh/day)
Last 30 Days (06/17/2026) 741.673 kWh (24.722 kWh/day) 863.682 kWh (28.789 kWh/day) 122.009 kWh (4.067 kWh/day)
Last One Year 6.729 MWh (18.435 kWh/day) 7.648 MWh (20.953 kWh/day) 0.919 MWh (2.518 kWh/day)
Lifetime Since PTO 39.593 MWh (17.659 kW/day) 43.366 MWh (19.342 kW/day) 3.773 MWh (1.683 kW/day)
Lifetime Since Install 39.627 MWh 43.946 MWh 4.319 MWh
Voltage/Current 125.4 V / 0.9 A, 125.4 V / 0.9 A 125.1 V / 1.4 A, 125.6 V / 0.5 A 125.3 V / 0.5 A, 125.5 V / -0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/28/2022 23:00 (6.8 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.226 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.190 1.462 0.453 4.550 0.000 kW
1.454 kWh
0.000 kW
8.725 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.184 1.410 0.431 4.323
03 - 202224****** IQ7+M [0] ---- 0.000 0.191 1.481 0.440 4.537
04 - 202232****** IQ7+ [0] ---- 0.000 0.190 1.485 0.447 4.512
05 - 202244****** IQ7+M [0] ---- 0.000 0.189 1.459 0.412 4.406
06 - 202245****** IQ7+M [0] ---- 0.000 0.183 1.428 0.434 4.318
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.261 1.208 0.455 4.679 0.000 kW
1.455 kWh
0.000 kW
7.274 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.260 1.385 0.441 5.244
09 - 202217****** IQ7+ [0] ---- 0.000 0.262 1.925 0.457 5.344
10 - 202244****** IQ7+M [0] ---- 0.000 0.258 1.474 0.469 5.467
11 - 202224****** IQ7+M [0] ---- 0.000 0.261 1.282 0.444 5.069
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.069 0.529 0.361 1.845 0.000 kW
0.557 kWh
0.000 kW
2.228 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.074 0.564 0.368 2.125
14 - 202216****** IQ7+ [0] ---- 0.000 0.075 0.578 0.366 2.135
15 - 202245****** IQ7+M [0] ---- 0.000 0.073 0.556 0.359 2.068
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
PCU NUM and LEVEL
Flag Error Count

Battery History
Voltage 53.30 V Current/Power -1.65 A (-87 W)
Remain Capacity/Energy 462.9 Ah (23.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 77.1 % State Of Health 100.0 %
Run Time 11d 16h 32m to empty Report Date 2022-12-28 23:53
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.