| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.889 kW | |||
|---|---|---|---|
| 09/28/2026 13:25 (2315 days) | Production | Consumption | NET Usage |
| Now | 1.116 kW | 0.227 kW | -0.889 kW |
| Today | 4.569 kWh (0.340 kW) | 5.459 kWh (0.406 kW) | 0.890 kWh (0.066 kW) |
| - This Week | 9.290 kWh (5.956 kWh/day) | 17.021 kWh (10.912 kWh/day) | 7.731 kWh (4.956 kWh/day) |
| - This Month | 481.200 kWh (17.460 kWh/day) | 466.364 kWh (16.922 kWh/day) | -14.836 kWh (-0.538 kWh/day) |
| - This Year | 5.772 MWh (21.332 kWh/day) | 5.627 MWh (20.798 kWh/day) | -0.145 MWh (-0.534 kWh/day) |
| Yesterday | 4.721 kWh (0.197 kW) | 11.562 kWh (0.482 kW) | 6.841 kWh (0.285 kW) |
| Last 7 Days | 93.565 kWh (13.366 kWh/day) | 102.246 kWh (14.607 kWh/day) | 8.681 kWh (1.240 kWh/day) |
| Last 30 Days (08/29/2026) | 545.505 kWh (18.183 kWh/day) | 583.653 kWh (19.455 kWh/day) | 38.148 kWh (1.272 kWh/day) |
| Last One Year | 6.830 MWh (18.711 kWh/day) | 7.380 MWh (20.219 kWh/day) | 0.550 MWh (1.508 kWh/day) |
| Lifetime Since PTO | 41.337 MWh (17.852 kW/day) | 45.138 MWh (19.493 kW/day) | 3.801 MWh (1.641 kW/day) |
| Lifetime Since Install | 41.371 MWh | 45.718 MWh | 4.347 MWh |
| Voltage/Current | 125.0 V / 4.5 A, 125.0 V / 4.5 A | 124.6 V / 1.3 A, 125.2 V / 0.5 A | 124.8 V / -3.1 A, 125.1 V / -4.0 A |
|
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 02/03/2024 23:55 (23.9 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.230 kW (0.013 kW/panel) | Today Energy | 23.261 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.234 | 1.288 | 0.235 | 1.590 | 0.000 kW 1.250 kWh |
0.000 kW 7.498 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.223 | 1.220 | 0.217 | 1.459 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.230 | 1.253 | 0.233 | 1.572 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.230 | 1.261 | 0.230 | 1.556 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.224 | 1.231 | 0.212 | 1.424 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.226 | 1.244 | 0.219 | 1.476 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.283 | 1.347 | 0.212 | 1.423 | 0.000 kW 1.543 kWh |
0.000 kW 7.715 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.284 | 1.527 | 0.215 | 1.454 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.283 | 1.654 | 0.212 | 1.435 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.278 | 1.617 | 0.213 | 1.441 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.285 | 1.570 | 0.216 | 1.457 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.119 | 0.549 | 0.208 | 1.386 | 0.000 kW 0.633 kWh |
0.000 kW 2.534 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.124 | 0.647 | 0.224 | 1.501 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.128 | 0.672 | 0.237 | 1.584 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.127 | 0.665 | 0.236 | 1.581 | |||
| yard | 16 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| battery | 17 - 122214****** | IQ7PD | [0] ---- | 0.230 | 0.230 | 5.514 | 5.526 | 8.939 | 0.115 kW 2.757 kWh |
0.230 kW 5.514 kWh |
| 18 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.50 V | Current/Power | -5.45 A (-0.286 kW) |
| Remain Capacity/Energy | 241.0 Ah (12.3 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
| State Of Charge | 40.6 % | State Of Health | 98.9 % |
| Run Time | 1d 20h 12m to empty | Report Date | 2024-02-03 23:58 |
|
|
|||
| Voltage | 52.47 V | Cell (MIN/MAX) | 3.274 V / 3.284 V (0.010 V) |
|---|---|---|---|
| Current/Power | -1.48 A (-77 W) | Runtime | 2d 6h 16m to empty |
| Remain Capacity/Energy | 80.3 Ah (4.1 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
| State Of Charge | 40.6 % | State Of Health | 98.8 % |
| Temperature | 16.5 °C | Cycle | 131 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2024-02-03 23:58 |
| Voltage | 52.52 V | Cell (MIN/MAX) | 3.282 V / 3.283 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.99 A (-51 W) | Runtime | 2d 23h 14m to empty |
| Remain Capacity/Energy | 70.5 Ah (3.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 70.9 % | State Of Health | 99.5 % |
| Temperature | 19.1 °C | Cycle | 72 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2024-02-03 23:58 |
| Voltage | 52.53 V | Cell (MIN/MAX) | 3.282 V / 3.284 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.97 A (-50 W) | Runtime | 2d 22h 19m to empty |
| Remain Capacity/Energy | 68.2 Ah (3.5 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 68.6 % | State Of Health | 99.5 % |
| Temperature | 17.7 °C | Cycle | 75 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2024-02-03 23:58 |
| Voltage | 52.51 V | Cell (MIN/MAX) | 3.280 V / 3.282 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.96 A (-50 W) | Runtime | 3d 0h 25m to empty |
| Remain Capacity/Energy | 69.4 Ah (3.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 69.7 % | State Of Health | 99.5 % |
| Temperature | 17.9 °C | Cycle | 77 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2024-02-03 23:59 |
| Voltage | 52.50 V | Cell (MIN/MAX) | 3.280 V / 3.281 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.02 A (-53 W) | Runtime | 2d 19h 55m to empty |
| Remain Capacity/Energy | 69.3 Ah (3.5 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 69.9 % | State Of Health | 99.2 % |
| Temperature | 18.8 °C | Cycle | 75 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2024-02-03 23:58 |