Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 2.381 kW | |||
---|---|---|---|
07/10/2025 20:48 (1870 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 2.381 kW | 2.381 kW |
Today | 16.102 kWh (0.773 kW) | 25.024 kWh (1.201 kW) | 8.922 kWh (0.428 kW) |
- This Week | 115.697 kWh (23.765 kWh/day) | 217.101 kWh (44.595 kWh/day) | 101.404 kWh (20.830 kWh/day) |
- This Month | 245.406 kWh (24.869 kWh/day) | 385.827 kWh (39.099 kWh/day) | 140.421 kWh (14.230 kWh/day) |
- This Year | 3.275 MWh (17.159 kWh/day) | 3.513 MWh (18.406 kWh/day) | 0.238 MWh (1.247 kWh/day) |
Yesterday | 25.046 kWh (1.044 kW) | 40.411 kWh (1.684 kW) | 15.365 kWh (0.640 kW) |
Last 7 Days | 187.533 kWh (26.791 kWh/day) | 299.677 kWh (42.813 kWh/day) | 112.144 kWh (16.021 kWh/day) |
Last 30 Days | 652.855 kWh (21.763 kWh/day) | 970.553 kWh (32.353 kWh/day) | 317.698 kWh (10.590 kWh/day) |
Last One Year | 6.296 MWh (17.249 kWh/day) | 6.482 MWh (17.760 kWh/day) | 0.186 MWh (0.511 kWh/day) |
Lifetime Since PTO | 32.726 MWh (17.492 kW/day) | 35.465 MWh (18.956 kW/day) | 2.739 MWh (1.464 kW/day) |
Lifetime Since Install | 32.760 MWh | 36.045 MWh | 3.285 MWh |
Voltage/Current | 124.5 V / 0.0 A, 124.5 V / 0.0 A | 124.6 V / 8.7 A, 124.4 V / 10.4 A | 124.6 V / 8.7 A, 124.5 V / 10.4 A |
![]() |
Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 07/09/2023 23:21 (14.3 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 11.803 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.152 | 0.707 | 0.976 | 10.929 | 0.000 kW 0.687 kWh |
0.000 kW 4.122 kWh |
02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.152 | 0.679 | 0.926 | 10.322 | |||
03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.157 | 0.703 | 0.961 | 10.597 | |||
04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.152 | 0.699 | 0.967 | 10.753 | |||
05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.144 | 0.652 | 0.855 | 9.737 | |||
06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.148 | 0.682 | 0.945 | 10.598 | |||
front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.138 | 0.632 | 0.855 | 9.941 | 0.000 kW 0.634 kWh |
0.000 kW 3.170 kWh |
08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.134 | 0.630 | 0.854 | 9.784 | |||
09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.141 | 0.638 | 0.865 | 9.879 | |||
10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.138 | 0.640 | 0.867 | 9.973 | |||
11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.136 | 0.630 | 0.876 | 10.143 | |||
back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.150 | 0.667 | 0.947 | 10.068 | 0.000 kW 0.712 kWh |
0.000 kW 2.848 kWh |
13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.151 | 0.701 | 0.985 | 10.234 | |||
14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.157 | 0.733 | 1.015 | 10.606 | |||
15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.160 | 0.746 | 1.022 | 10.645 | |||
wind | 16 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.230 | 1.664 | 1.134 | 8.594 | 0.000 kW 1.664 kWh |
0.000 kW 1.664 kWh |
![]() ![]() ![]() |
Battery History | |||
---|---|---|---|
Voltage | 52.62 V | Current/Power | -1.50 A (-78 W) |
Remain Capacity/Energy | 295.1 Ah (15.1 kWh) | Full Capacity/Energy | 593.1 Ah (30.4 kWh) |
State Of Charge | 49.7 % | State Of Health | 98.9 % |
Run Time | 8d 4h 42m to empty | Report Date | 2023-07-09 23:57 |
![]() ![]() |
Voltage | 52.61 V | Cell (MIN/MAX) | 3.282 V / 3.292 V (0.010 V) |
---|---|---|---|
Current/Power | -0.53 A (-27 W) | Runtime | 7d 17h 33m to empty |
Remain Capacity/Energy | 98.3 Ah (5.0 kWh) | Full Capacity/Energy | 197.7 Ah (10.1 kWh) |
State Of Charge | 49.7 % | State Of Health | 98.8 % |
Temperature | 25.0 °C | Cycle | 109 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-09 23:57 |
Voltage | 52.61 V | Cell (MIN/MAX) | 3.287 V / 3.289 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 61.7 Ah (3.2 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 62.0 % | State Of Health | 99.5 % |
Temperature | 24.5 °C | Cycle | 55 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-09 23:58 |
Voltage | 52.65 V | Cell (MIN/MAX) | 3.289 V / 3.290 V (0.001 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 59.5 Ah (3.0 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 59.8 % | State Of Health | 99.5 % |
Temperature | 25.7 °C | Cycle | 58 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-09 23:57 |
Voltage | 52.62 V | Cell (MIN/MAX) | 3.287 V / 3.289 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 59.3 Ah (3.0 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
State Of Charge | 59.6 % | State Of Health | 99.5 % |
Temperature | 26.3 °C | Cycle | 59 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-09 23:58 |
Voltage | 52.62 V | Cell (MIN/MAX) | 3.287 V / 3.289 V (0.002 V) |
---|---|---|---|
Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
Remain Capacity/Energy | 59.8 Ah (3.1 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
State Of Charge | 60.3 % | State Of Health | 99.2 % |
Temperature | 24.7 °C | Cycle | 58 |
MOSFET | CFET = ON, DFET = ON | Reported | 2023-07-09 23:57 |