Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.721 kW
09/23/2025 15:42 (1945 days) Production Consumption NET Usage
Now 2.102 kW 0.381 kW -1.721 kW
Today 14.791 kWh (0.939 kW) 6.393 kWh (0.406 kW) -8.398 kWh (-0.533 kW)
  - This Week 51.393 kWh (19.359 kWh/day) 38.578 kWh (14.532 kWh/day) -12.815 kWh (-4.827 kWh/day)
  - This Month 484.005 kWh (21.364 kWh/day) 501.144 kWh (22.121 kWh/day) 17.139 kWh (0.757 kWh/day)
  - This Year 4.991 MWh (18.789 kWh/day) 5.672 MWh (21.351 kWh/day) 0.681 MWh (2.562 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.442 MWh (17.702 kW/day) 37.624 MWh (19.337 kW/day) 3.182 MWh (1.635 kW/day)
Lifetime Since Install 34.476 MWh 38.204 MWh 3.728 MWh
Voltage/Current 123.7 V / 8.5 A, 123.7 V / 8.5 A 123.7 V / 1.6 A, 123.8 V / 1.5 A 123.7 V / -6.9 A, 123.7 V / -7.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/01/2020 23:44 (11.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.257 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.075 1.681 7.058 0.000 kW
1.053 kWh
0.000 kW
6.318 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.280 1.060 1.664 7.095
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.073 1.686 7.044
04 - 202232****** IQ7+ [5] VCOP 0.000 0.281 1.059 1.676 7.076
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.025 1.669 7.051
06 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.025 1.652 7.061
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 0.998 1.828 7.422 0.000 kW
1.001 kWh
0.000 kW
5.003 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 0.876 1.768 7.135
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 1.044 1.813 7.361
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.050 1.835 7.382
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.034 1.830 7.373
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.221 0.991 1.065 5.337 0.000 kW
0.984 kWh
0.000 kW
3.937 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.220 0.985 1.046 5.299
14 - 202216****** IQ7+ [5] VCOP 0.000 0.219 0.990 1.077 5.401
15 - 202245****** IQ7+M [5] VCOP 0.000 0.221 0.971 1.056 5.404
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.11 A (9.810 kW)
Remain Capacity/Energy 567.3 Ah (29.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.0 % State Of Health 98.5 %
Run Time 8m to full Report Date 2020-10-01 23:13
voltag, current for each battery pack voltage, current, and SOC