Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.071 kW
09/23/2025 11:55 (1945 days) Production Consumption NET Usage
Now 3.490 kW 0.419 kW -3.071 kW
Today 5.084 kWh (0.425 kW) 4.849 kWh (0.406 kW) -0.235 kWh (-0.020 kW)
  - This Week 41.686 kWh (16.696 kWh/day) 37.034 kWh (14.833 kWh/day) -4.652 kWh (-1.863 kWh/day)
  - This Month 474.298 kWh (21.083 kWh/day) 499.600 kWh (22.208 kWh/day) 25.302 kWh (1.125 kWh/day)
  - This Year 4.982 MWh (18.763 kWh/day) 5.670 MWh (21.357 kWh/day) 0.689 MWh (2.594 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.433 MWh (17.699 kW/day) 37.622 MWh (19.338 kW/day) 3.190 MWh (1.640 kW/day)
Lifetime Since Install 34.466 MWh 38.202 MWh 3.736 MWh
Voltage/Current 126.1 V / 13.8 A, 126.1 V / 13.8 A 125.6 V / 1.7 A, 126.4 V / 1.6 A 125.9 V / -12.2 A, 126.2 V / -12.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/06/2020 21:59 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.285 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.059 1.156 6.439 0.000 kW
1.054 kWh
0.000 kW
6.325 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.213 1.038 1.143 6.244
03 - 202224****** IQ7+M [5] VCOP 0.000 0.216 1.054 1.156 6.345
04 - 202232****** IQ7+ [5] VCOP 0.000 0.215 1.050 1.145 6.288
05 - 202244****** IQ7+M [5] VCOP 0.000 0.214 1.068 1.168 6.395
06 - 202245****** IQ7+M [5] VC-- 0.000 0.212 1.055 1.151 6.470
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.264 1.328 1.389 7.477 0.000 kW
1.349 kWh
0.000 kW
6.745 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.204 1.283 6.901
09 - 202217****** IQ7+ [5] VCOP 0.000 0.265 1.425 1.488 7.959
10 - 202244****** IQ7+M [5] VCOP 0.000 0.264 1.415 1.488 7.956
11 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.373 1.422 7.647
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.118 0.513 0.605 3.761 0.000 kW
0.554 kWh
0.000 kW
2.215 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.119 0.572 0.664 4.010
14 - 202216****** IQ7+ [5] VCOP 0.000 0.119 0.571 0.664 4.054
15 - 202245****** IQ7+M [5] VCOP 0.000 0.117 0.558 0.649 3.970
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.02 V Current/Power 178.15 A (10.158 kW)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-06 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.02 V Cell (MIN/MAX) 3.552 V / 3.569 V (0.017 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 197.0 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-06 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.560 V 3.561 V 3.558 V 3.561 V 3.563 V 3.563 V 3.563 V 3.566 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.552 V 3.564 V 3.567 V 3.568 V 3.565 V 3.568 V 3.565 V 3.569 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -