Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.396 kW
09/23/2025 09:20 (1945 days) Production Consumption NET Usage
Now 0.615 kW 0.219 kW -0.396 kW
Today 0.812 kWh (0.087 kW) 3.832 kWh (0.409 kW) 3.020 kWh (0.322 kW)
  - This Week 37.414 kWh (15.661 kWh/day) 36.017 kWh (15.076 kWh/day) -1.397 kWh (-0.585 kWh/day)
  - This Month 470.026 kWh (20.994 kWh/day) 498.583 kWh (22.269 kWh/day) 28.557 kWh (1.275 kWh/day)
  - This Year 4.977 MWh (18.755 kWh/day) 5.669 MWh (21.362 kWh/day) 0.692 MWh (2.607 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.428 MWh (17.697 kW/day) 37.621 MWh (19.339 kW/day) 3.193 MWh (1.641 kW/day)
Lifetime Since Install 34.462 MWh 38.201 MWh 3.739 MWh
Voltage/Current 124.9 V / 2.5 A, 124.9 V / 2.5 A 124.8 V / 1.1 A, 124.9 V / 0.6 A 124.9 V / -1.3 A, 124.9 V / -1.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/29/2020 21:42 (9.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.771 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.206 0.984 0.514 3.817 0.000 kW
0.971 kWh
0.000 kW
5.824 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.953 0.490 3.699
03 - 202224****** IQ7+M [5] VCOP 0.000 0.205 0.938 0.482 3.688
04 - 202232****** IQ7+ [5] VCOP 0.000 0.204 0.890 0.463 3.538
05 - 202244****** IQ7+M [5] VCOP 0.000 0.206 1.037 0.549 3.908
06 - 202245****** IQ7+M [5] VCOP 0.000 0.203 1.022 0.549 3.890
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 1.241 0.588 4.413 0.000 kW
1.250 kWh
0.000 kW
6.252 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.263 1.093 0.457 4.063
09 - 202217****** IQ7+ [5] VCOP 0.000 0.263 1.341 0.643 4.699
10 - 202244****** IQ7+M [5] VCOP 0.000 0.262 1.340 0.638 4.693
11 - 202224****** IQ7+M [5] VCOP 0.000 0.260 1.237 0.577 4.427
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.092 0.377 0.360 2.193 0.000 kW
0.424 kWh
0.000 kW
1.695 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.096 0.449 0.368 2.350
14 - 202216****** IQ7+ [5] VCOP 0.000 0.096 0.441 0.370 2.351
15 - 202245****** IQ7+M [5] VCOP 0.000 0.092 0.428 0.361 2.292
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.03 V Current/Power 178.16 A (10.160 kW)
Remain Capacity/Energy 589.2 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-29 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.