Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.207 kW
09/23/2025 11:52 (1945 days) Production Consumption NET Usage
Now 3.626 kW 0.419 kW -3.207 kW
Today 4.900 kWh (0.412 kW) 4.826 kWh (0.406 kW) -0.074 kWh (-0.006 kW)
  - This Week 41.502 kWh (16.637 kWh/day) 37.011 kWh (14.837 kWh/day) -4.491 kWh (-1.800 kWh/day)
  - This Month 474.114 kWh (21.077 kWh/day) 499.577 kWh (22.209 kWh/day) 25.463 kWh (1.132 kWh/day)
  - This Year 4.981 MWh (18.763 kWh/day) 5.670 MWh (21.358 kWh/day) 0.689 MWh (2.595 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.432 MWh (17.699 kW/day) 37.622 MWh (19.338 kW/day) 3.190 MWh (1.640 kW/day)
Lifetime Since Install 34.466 MWh 38.202 MWh 3.736 MWh
Voltage/Current 126.2 V / 14.4 A, 126.2 V / 14.4 A 125.7 V / 1.7 A, 126.5 V / 1.7 A 125.9 V / -12.7 A, 126.3 V / -12.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/30/2020 21:16 (8.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.685 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.019 0.048 0.984 4.643 0.000 kW
0.047 kWh
0.000 kW
0.283 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.018 0.047 0.953 4.497
03 - 202224****** IQ7+M [5] VCOP 0.000 0.018 0.049 0.938 4.467
04 - 202232****** IQ7+ [5] VCOP 0.000 0.018 0.047 0.890 4.272
05 - 202244****** IQ7+M [5] VCOP 0.000 0.018 0.046 1.037 4.792
06 - 202245****** IQ7+M [5] VC-- 0.000 0.018 0.047 1.022 4.758
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.017 0.042 1.241 5.513 0.000 kW
0.042 kWh
0.000 kW
0.208 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.017 0.042 1.093 5.017
09 - 202217****** IQ7+ [5] VCOP 0.000 0.016 0.041 1.341 5.899
10 - 202244****** IQ7+M [5] VCOP 0.000 0.017 0.042 1.340 5.890
11 - 202224****** IQ7+M [5] VCOP 0.000 0.017 0.041 1.237 5.524
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.018 0.048 0.377 2.412 0.000 kW
0.049 kWh
0.000 kW
0.194 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.018 0.049 0.449 2.639
14 - 202216****** IQ7+ [5] VCOP 0.000 0.018 0.050 0.441 2.629
15 - 202245****** IQ7+M [5] VCOP 0.000 0.018 0.048 0.428 2.561
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.24 V Current/Power 166.27 A (8.853 kW)
Remain Capacity/Energy 570.9 Ah (29.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.6 % State Of Health 98.5 %
Run Time 7m to full Report Date 2020-11-30 23:32
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.24 V Cell (MIN/MAX) 3.322 V / 3.332 V (0.010 V)
Current/Power -0.52 A (-27 W) Runtime 15d 8h 5m to empty
Remain Capacity/Energy 190.3 Ah (9.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 96.6 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-11-30 23:32
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.326 V 3.327 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.328 V 3.328 V 3.329 V 3.329 V 3.330 V 3.331 V 3.332 V 3.332 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -