Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.029 kW
09/23/2025 10:51 (1945 days) Production Consumption NET Usage
Now 2.219 kW 0.190 kW -2.029 kW
Today 2.604 kWh (0.239 kW) 4.493 kWh (0.413 kW) 1.889 kWh (0.174 kW)
  - This Week 39.206 kWh (15.987 kWh/day) 36.678 kWh (14.957 kWh/day) -2.528 kWh (-1.031 kWh/day)
  - This Month 471.818 kWh (21.014 kWh/day) 499.244 kWh (22.236 kWh/day) 27.426 kWh (1.222 kWh/day)
  - This Year 4.979 MWh (18.757 kWh/day) 5.670 MWh (21.360 kWh/day) 0.691 MWh (2.602 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.430 MWh (17.698 kW/day) 37.622 MWh (19.338 kW/day) 3.192 MWh (1.641 kW/day)
Lifetime Since Install 34.464 MWh 38.202 MWh 3.738 MWh
Voltage/Current 125.6 V / 8.8 A, 125.6 V / 8.8 A 125.4 V / 0.9 A, 126.1 V / 0.7 A 125.5 V / -8.0 A, 125.9 V / -8.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/10/2020 19:24 (8.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.073 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.218 0.764 0.318 3.872 0.000 kW
0.757 kWh
0.000 kW
4.542 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.216 0.742 0.309 3.761
03 - 202224****** IQ7+M [5] VCOP 0.000 0.216 0.726 0.320 3.738
04 - 202232****** IQ7+ [5] VCOP 0.000 0.215 0.681 0.303 3.558
05 - 202244****** IQ7+M [5] VCOP 0.000 0.217 0.809 0.323 4.026
06 - 202245****** IQ7+M [5] VCOP 0.000 0.215 0.821 0.325 3.996
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.287 0.999 0.331 4.785 0.000 kW
0.831 kWh
0.000 kW
4.153 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.051 4.150
09 - 202217****** IQ7+ [5] VCOP 0.000 0.289 1.097 0.347 5.110
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.077 0.340 5.078
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 0.980 0.332 4.802
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.099 0.313 0.278 1.974 0.000 kW
0.345 kWh
0.000 kW
1.378 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.110 0.360 0.286 2.170
14 - 202216****** IQ7+ [5] VCOP 0.000 0.110 0.358 0.291 2.168
15 - 202245****** IQ7+M [5] VCOP 0.000 0.108 0.347 0.279 2.111
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.74 V Current/Power 167.86 A (9.020 kW)
Remain Capacity/Energy 498.3 Ah (25.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Run Time 33m to full Report Date 2020-12-10 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.74 V Cell (MIN/MAX) 3.352 V / 3.362 V (0.010 V)
Current/Power 4.00 A (0.215 kW) Runtime 7h 43m to full
Remain Capacity/Energy 166.1 Ah (8.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 84.3 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-10 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.352 V 3.355 V 3.354 V 3.356 V 3.356 V 3.357 V 3.359 V 3.358 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.357 V 3.360 V 3.359 V 3.361 V 3.360 V 3.362 V 3.362 V 3.361 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -