Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.472 kW
07/18/2025 09:41 (1878 days) Production Consumption NET Usage
Now 1.743 kW 0.271 kW -1.472 kW
Today 2.850 kWh (0.294 kW) 9.113 kWh (0.940 kW) 6.263 kWh (0.646 kW)
  - This Week 112.147 kWh (20.749 kWh/day) 184.659 kWh (34.165 kWh/day) 72.512 kWh (13.416 kWh/day)
  - This Month 409.225 kWh (23.512 kWh/day) 681.517 kWh (39.157 kWh/day) 272.292 kWh (15.645 kWh/day)
  - This Year 3.439 MWh (17.333 kWh/day) 3.809 MWh (19.197 kWh/day) 0.370 MWh (1.864 kWh/day)
Yesterday 22.953 kWh (0.956 kW) 36.558 kWh (1.523 kW) 13.605 kWh (0.567 kW)
Last 7 Days 160.969 kWh (22.996 kWh/day) 281.713 kWh (40.246 kWh/day) 120.744 kWh (17.250 kWh/day)
Last 30 Days 708.321 kWh (23.610 kWh/day) 1108.410 kWh (36.946 kWh/day) 400.089 kWh (13.336 kWh/day)
Last One Year 6.254 MWh (17.135 kWh/day) 6.567 MWh (17.993 kWh/day) 0.313 MWh (0.858 kWh/day)
Lifetime Since PTO 32.890 MWh (17.509 kW/day) 35.761 MWh (19.038 kW/day) 2.871 MWh (1.528 kW/day)
Lifetime Since Install 32.924 MWh 36.341 MWh 3.417 MWh
Voltage/Current 124.9 V / 7.0 A, 124.9 V / 7.0 A 124.6 V / 1.6 A, 125.1 V / 0.6 A 124.7 V / -5.4 A, 125.0 V / -6.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/30/2020 22:09 (9.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.777 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.177 0.408 0.088 2.548 0.000 kW
0.401 kWh
0.000 kW
2.409 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.164 0.366 0.085 2.508
03 - 202224****** IQ7+M [5] VCOP 0.000 0.173 0.422 0.088 2.567
04 - 202232****** IQ7+ [5] VCOP 0.000 0.174 0.410 0.086 2.522
05 - 202244****** IQ7+M [5] VCOP 0.000 0.176 0.395 0.085 2.497
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.409 0.086 2.504
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.205 0.393 0.077 2.515 0.000 kW
0.392 kWh
0.000 kW
1.960 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.203 0.389 0.077 2.445
09 - 202217****** IQ7+ [5] VCOP 0.000 0.203 0.403 0.077 2.577
10 - 202244****** IQ7+M [5] VCOP 0.000 0.206 0.406 0.078 2.589
11 - 202224****** IQ7+M [5] VCOP 0.000 0.199 0.369 0.077 2.549
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.084 0.343 0.084 2.138 0.000 kW
0.352 kWh
0.000 kW
1.408 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.344 0.085 2.166
14 - 202216****** IQ7+ [5] VCOP 0.000 0.088 0.369 0.088 2.196
15 - 202245****** IQ7+M [5] VCOP 0.000 0.086 0.353 0.085 2.155
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.02 V Current/Power 178.00 A (10.150 kW)
Remain Capacity/Energy 589.5 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-30 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.02 V Cell (MIN/MAX) 3.554 V / 3.568 V (0.014 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.5 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-30 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.561 V 3.560 V 3.565 V 3.565 V 3.562 V 3.554 V 3.567 V 3.567 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.565 V 3.554 V 3.566 V 3.567 V 3.562 V 3.567 V 3.564 V 3.568 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -