Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.117 kW
09/23/2025 08:36 (1945 days) Production Consumption NET Usage
Now 0.407 kW 0.290 kW -0.117 kW
Today 0.305 kWh (0.035 kW) 3.573 kWh (0.414 kW) 3.268 kWh (0.378 kW)
  - This Week 36.907 kWh (15.647 kWh/day) 35.758 kWh (15.160 kWh/day) -1.149 kWh (-0.487 kWh/day)
  - This Month 469.519 kWh (20.999 kWh/day) 498.324 kWh (22.288 kWh/day) 28.805 kWh (1.288 kWh/day)
  - This Year 4.977 MWh (18.755 kWh/day) 5.669 MWh (21.364 kWh/day) 0.692 MWh (2.609 kWh/day)
Yesterday 14.668 kWh (0.612 kW) 15.680 kWh (0.654 kW) 1.012 kWh (0.042 kW)
Last 7 Days 137.378 kWh (19.627 kWh/day) 116.585 kWh (16.656 kWh/day) -20.793 kWh (-2.971 kWh/day)
Last 30 Days 665.748 kWh (22.192 kWh/day) 643.337 kWh (21.445 kWh/day) -22.411 kWh (-0.747 kWh/day)
Last One Year 6.270 MWh (17.177 kWh/day) 7.211 MWh (19.755 kWh/day) 0.941 MWh (2.578 kWh/day)
Lifetime Since PTO 34.428 MWh (17.697 kW/day) 37.621 MWh (19.339 kW/day) 3.193 MWh (1.641 kW/day)
Lifetime Since Install 34.462 MWh 38.201 MWh 3.739 MWh
Voltage/Current 124.6 V / 1.6 A, 124.6 V / 1.6 A 124.5 V / 1.7 A, 124.8 V / 0.6 A 124.6 V / 0.1 A, 124.7 V / -1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/09/2021 21:52 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.360 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.236 0.820 0.644 4.192 0.000 kW
0.789 kWh
0.000 kW
4.732 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.755 0.584 3.883
03 - 202224****** IQ7+M [5] VCOP 0.000 0.231 0.752 0.574 3.885
04 - 202232****** IQ7+ [5] VC-- 0.000 0.234 0.731 0.530 3.710
05 - 202244****** IQ7+M [5] VCOP 0.000 0.228 0.828 0.628 4.163
06 - 202245****** IQ7+M [5] VCOP 0.000 0.229 0.846 0.658 4.292
front 07 - 202206****** IQ7+ [5] VC-- 0.000 0.294 0.959 0.729 5.192 0.000 kW
0.956 kWh
0.000 kW
4.780 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 0.794 0.610 4.519
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.055 0.799 5.514
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.040 0.783 5.470
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 0.932 0.721 5.133
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.111 0.438 0.404 2.143 0.000 kW
0.462 kWh
0.000 kW
1.848 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.120 0.475 0.423 2.354
14 - 202216****** IQ7+ [5] VCOP 0.000 0.118 0.475 0.424 2.354
15 - 202245****** IQ7+M [5] VCOP 0.000 0.114 0.461 0.412 2.295
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.22 V Current/Power 166.21 A (8.845 kW)
Remain Capacity/Energy 479.4 Ah (24.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 81.1 % State Of Health 98.5 %
Run Time 40m to full Report Date 2021-01-09 23:35
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.22 V Cell (MIN/MAX) 3.320 V / 3.330 V (0.010 V)
Current/Power -0.26 A (-13 W) Runtime 26d 0h 13m to empty
Remain Capacity/Energy 159.8 Ah (8.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 81.1 % State Of Health 98.5 %
Temperature 18.5 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-09 23:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.322 V 3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.326 V 3.327 V 3.327 V 3.328 V 3.329 V 3.330 V 3.330 V 3.330 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -