| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.587 kW | |||
|---|---|---|---|
| 04/05/2026 20:43 (2139 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.587 kW | 0.587 kW |
| Today | 4.461 kWh (0.215 kW) | 17.067 kWh (0.823 kW) | 12.606 kWh (0.608 kW) |
| - This Week | 4.461 kWh (5.164 kWh/day) | 17.067 kWh (19.758 kWh/day) | 12.606 kWh (14.594 kWh/day) |
| - This Month | 57.066 kWh (11.733 kWh/day) | 78.126 kWh (16.063 kWh/day) | 21.060 kWh (4.330 kWh/day) |
| - This Year | 1.286 MWh (13.561 kWh/day) | 1.643 MWh (17.324 kWh/day) | 0.357 MWh (3.763 kWh/day) |
| Yesterday | 17.277 kWh (0.720 kW) | 15.635 kWh (0.651 kW) | -1.642 kWh (-0.068 kW) |
| Last 7 Days | 101.302 kWh (14.472 kWh/day) | 102.615 kWh (14.659 kWh/day) | 1.313 kWh (0.188 kWh/day) |
| Last 30 Days (03/06/2026) | 564.904 kWh (18.830 kWh/day) | 454.753 kWh (15.158 kWh/day) | -110.151 kWh (-3.672 kWh/day) |
| Last One Year | 6.104 MWh (16.723 kWh/day) | 7.841 MWh (21.482 kWh/day) | 1.737 MWh (4.759 kWh/day) |
| Lifetime Since PTO | 36.852 MWh (17.222 kW/day) | 41.154 MWh (19.232 kW/day) | 4.302 MWh (2.010 kW/day) |
| Lifetime Since Install | 36.886 MWh | 41.734 MWh | 4.848 MWh |
| Voltage/Current | 123.9 V / 0.0 A, 123.9 V / 0.0 A | 123.9 V / 3.2 A, 123.9 V / 1.5 A | 123.9 V / 3.2 A, 123.9 V / 1.5 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 11/09/2021 21:53 (9.8 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 14.469 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.204 | 1.052 | 1.109 | 7.098 | 0.000 kW 1.011 kWh |
0.000 kW 6.063 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.197 | 0.957 | 1.039 | 6.615 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.201 | 1.043 | 1.083 | 7.005 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.201 | 0.941 | 1.074 | 6.822 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.201 | 1.038 | 1.092 | 6.937 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.196 | 1.032 | 1.053 | 6.734 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.250 | 1.214 | 1.289 | 7.920 | 0.000 kW 1.247 kWh |
0.000 kW 6.236 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.250 | 1.071 | 1.130 | 6.950 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.251 | 1.364 | 1.471 | 8.635 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.247 | 1.323 | 1.430 | 8.469 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.250 | 1.264 | 1.356 | 8.167 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.112 | 0.519 | 0.564 | 4.159 | 0.000 kW 0.543 kWh |
0.000 kW 2.170 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.111 | 0.563 | 0.621 | 4.405 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.111 | 0.543 | 0.624 | 4.450 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.109 | 0.545 | 0.611 | 4.366 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.10 V | Current/Power | -4.30 A (-0.228 kW) |
| Remain Capacity/Energy | 409.5 Ah (21.0 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 68.2 % | State Of Health | 100.0 % |
| Run Time | 3d 23h 13m to empty | Report Date | 2021-11-09 23:58 |
|
|||
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.315 V / 3.327 V (0.012 V) |
|---|---|---|---|
| Current/Power | -1.80 A (-95 W) | Runtime | 3d 3h 50m to empty |
| Remain Capacity/Energy | 136.5 Ah (7.0 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 68.2 % | State Of Health | 100.0 % |
| Temperature | 23.0 °C | Cycle | 48 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-11-09 23:58 |
| Voltage | 53.09 V | Cell (MIN/MAX) | 3.317 V / 3.319 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 77.9 Ah (4.0 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 77.9 % | State Of Health | 100.0 % |
| Temperature | 25.9 °C | Cycle | 7 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-11-09 23:59 |
| Voltage | 53.13 V | Cell (MIN/MAX) | 3.319 V / 3.321 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 82.8 Ah (4.2 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 82.8 % | State Of Health | 100.0 % |
| Temperature | 24.1 °C | Cycle | 7 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-11-09 23:59 |
| Voltage | 53.07 V | Cell (MIN/MAX) | 3.316 V / 3.318 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 84.5 Ah (4.3 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 84.5 % | State Of Health | 100.0 % |
| Temperature | 23.4 °C | Cycle | 7 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-11-09 23:58 |
| Voltage | 53.09 V | Cell (MIN/MAX) | 3.317 V / 3.319 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.64 A (-33 W) | Runtime | 5d 8h 8m to empty |
| Remain Capacity/Energy | 82.0 Ah (4.2 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 82.3 % | State Of Health | 99.7 % |
| Temperature | 25.4 °C | Cycle | 7 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2021-11-09 23:59 |