Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.433 kW
09/22/2025 20:18 (1944 days) Production Consumption NET Usage
Now 0.000 kW 0.433 kW 0.433 kW
Today 14.668 kWh (0.722 kW) 13.206 kWh (0.650 kW) -1.462 kWh (-0.072 kW)
  - This Week 36.602 kWh (19.827 kWh/day) 29.711 kWh (16.094 kWh/day) -6.891 kWh (-3.733 kWh/day)
  - This Month 469.214 kWh (21.478 kWh/day) 492.277 kWh (22.534 kWh/day) 23.063 kWh (1.056 kWh/day)
  - This Year 4.977 MWh (18.790 kWh/day) 5.663 MWh (21.382 kWh/day) 0.686 MWh (2.592 kWh/day)
Yesterday 21.934 kWh (0.914 kW) 16.505 kWh (0.688 kW) -5.429 kWh (-0.226 kW)
Last 7 Days 145.623 kWh (20.802 kWh/day) 118.817 kWh (16.973 kWh/day) -26.806 kWh (-3.829 kWh/day)
Last 30 Days 680.721 kWh (22.690 kWh/day) 660.764 kWh (22.025 kWh/day) -19.957 kWh (-0.665 kWh/day)
Last One Year 6.278 MWh (17.201 kWh/day) 7.199 MWh (19.724 kWh/day) 0.921 MWh (2.522 kWh/day)
Lifetime Since PTO 34.427 MWh (17.702 kW/day) 37.615 MWh (19.341 kW/day) 3.188 MWh (1.639 kW/day)
Lifetime Since Install 34.461 MWh 38.195 MWh 3.734 MWh
Voltage/Current 125.4 V / 0.0 A, 125.4 V / 0.0 A 125.2 V / 1.9 A, 125.5 V / 1.5 A 125.3 V / 1.9 A, 125.4 V / 1.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/05/2021 23:50 (12.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.750 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.214 0.544 1.449 9.060 0.000 kW
0.530 kWh
0.000 kW
3.182 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.215 0.523 1.422 8.735
03 - 202224****** IQ7+M [0] ---- 0.000 0.208 0.542 1.439 8.963
04 - 202232****** IQ7+ [0] ---- 0.000 0.212 0.538 1.442 9.029
05 - 202244****** IQ7+M [0] ---- 0.000 0.213 0.513 1.405 8.324
06 - 202245****** IQ7+M [0] ---- 0.000 0.215 0.523 1.420 8.660
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.223 0.506 1.398 8.385 0.000 kW
0.510 kWh
0.000 kW
2.552 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.210 0.504 1.420 8.462
09 - 202217****** IQ7+ [0] ---- 0.000 0.212 0.512 1.404 8.463
10 - 202244****** IQ7+M [0] ---- 0.000 0.217 0.518 1.444 8.672
11 - 202224****** IQ7+M [0] ---- 0.000 0.217 0.512 1.437 8.631
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.159 0.502 1.266 8.711 0.000 kW
0.504 kWh
0.000 kW
2.016 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.143 0.498 1.229 8.470
14 - 202216****** IQ7+ [0] ---- 0.000 0.159 0.512 1.280 8.766
15 - 202245****** IQ7+M [0] ---- 0.000 0.160 0.503 1.263 8.624
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Battery History
Voltage 53.16 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 500.4 Ah (25.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.4 % State Of Health 100.0 %
Run Time 13d 21h 36m to empty Report Date 2021-05-05 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.