Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.030 kW
04/05/2026 14:31 (2139 days) Production Consumption NET Usage
Now 0.625 kW 0.595 kW -0.030 kW
Today 2.962 kWh (0.204 kW) 11.930 kWh (0.822 kW) 8.968 kWh (0.618 kW)
  - This Week 2.962 kWh (4.896 kWh/day) 11.930 kWh (19.718 kWh/day) 8.968 kWh (14.822 kWh/day)
  - This Month 55.567 kWh (12.066 kWh/day) 72.989 kWh (15.850 kWh/day) 17.422 kWh (3.783 kWh/day)
  - This Year 1.285 MWh (13.583 kWh/day) 1.638 MWh (17.318 kWh/day) 0.353 MWh (3.735 kWh/day)
Yesterday 17.277 kWh (0.720 kW) 15.635 kWh (0.651 kW) -1.642 kWh (-0.068 kW)
Last 7 Days 109.676 kWh (15.668 kWh/day) 114.469 kWh (16.353 kWh/day) 4.793 kWh (0.685 kWh/day)
Last 30 Days (03/06/2026) 564.234 kWh (18.808 kWh/day) 455.313 kWh (15.177 kWh/day) -108.921 kWh (-3.631 kWh/day)
Last One Year 6.103 MWh (16.721 kWh/day) 7.840 MWh (21.480 kWh/day) 1.737 MWh (4.759 kWh/day)
Lifetime Since PTO 36.851 MWh (17.223 kW/day) 41.149 MWh (19.232 kW/day) 4.298 MWh (2.009 kW/day)
Lifetime Since Install 36.885 MWh 41.729 MWh 4.844 MWh
Voltage/Current 125.0 V / 2.5 A, 125.0 V / 2.5 A 124.9 V / 3.2 A, 125.1 V / 1.5 A 124.9 V / 0.7 A, 125.0 V / -1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/22/2022 21:43 (9.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.645 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.230 1.239 1.127 4.805 0.000 kW
1.196 kWh
0.000 kW
7.175 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.223 1.148 1.064 4.481
03 - 202224****** IQ7+M [5] VCOP 0.000 0.229 1.203 1.134 4.783
04 - 202232****** IQ7+ [5] VCOP 0.000 0.230 1.192 1.107 4.664
05 - 202244****** IQ7+M [5] VCOP 0.000 0.226 1.220 1.115 4.670
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 1.174 1.074 4.543
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.464 1.332 5.427 0.000 kW
1.453 kWh
0.000 kW
7.263 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.280 1.279 5.017
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 1.542 1.416 5.725
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.519 1.382 5.603
11 - 202224****** IQ7+M [5] VCOP 0.000 0.288 1.459 1.373 5.412
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.112 0.497 0.483 2.567 0.000 kW
0.552 kWh
0.000 kW
2.207 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.115 0.575 0.562 2.755
14 - 202216****** IQ7+ [5] VCOP 0.000 0.116 0.576 0.566 2.771
15 - 202245****** IQ7+M [5] VCOP 0.000 0.114 0.559 0.555 2.706
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.