Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.592 kW
09/22/2025 09:27 (1944 days) Production Consumption NET Usage
Now 0.989 kW 0.397 kW -0.592 kW
Today 1.178 kWh (0.125 kW) 4.342 kWh (0.459 kW) 3.164 kWh (0.335 kW)
  - This Week 23.112 kWh (16.580 kWh/day) 20.847 kWh (14.955 kWh/day) -2.265 kWh (-1.625 kWh/day)
  - This Month 455.724 kWh (21.301 kWh/day) 483.413 kWh (22.596 kWh/day) 27.689 kWh (1.294 kWh/day)
  - This Year 4.963 MWh (18.771 kWh/day) 5.654 MWh (21.385 kWh/day) 0.691 MWh (2.614 kWh/day)
Yesterday 21.934 kWh (0.914 kW) 16.505 kWh (0.688 kW) -5.429 kWh (-0.226 kW)
Last 7 Days 145.623 kWh (20.802 kWh/day) 118.817 kWh (16.973 kWh/day) -26.806 kWh (-3.829 kWh/day)
Last 30 Days 680.721 kWh (22.690 kWh/day) 660.764 kWh (22.025 kWh/day) -19.957 kWh (-0.665 kWh/day)
Last One Year 6.278 MWh (17.201 kWh/day) 7.199 MWh (19.724 kWh/day) 0.921 MWh (2.522 kWh/day)
Lifetime Since PTO 34.414 MWh (17.699 kW/day) 37.606 MWh (19.341 kW/day) 3.192 MWh (1.642 kW/day)
Lifetime Since Install 34.448 MWh 38.186 MWh 3.738 MWh
Voltage/Current 126.1 V / 3.9 A, 126.1 V / 3.9 A 125.9 V / 2.0 A, 126.4 V / 1.2 A 126.0 V / -2.0 A, 126.3 V / -2.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/29/2021 21:50 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.141 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.195 0.504 1.377 5.208 0.000 kW
0.495 kWh
0.000 kW
2.968 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.194 0.485 1.298 4.919
03 - 202224****** IQ7+M [5] VCOP 0.000 0.192 0.506 1.356 5.160
04 - 202232****** IQ7+ [5] VCOP 0.000 0.195 0.502 1.291 4.986
05 - 202244****** IQ7+M [5] VCOP 0.000 0.191 0.483 1.356 5.031
06 - 202245****** IQ7+M [5] VCOP 0.000 0.195 0.488 1.310 4.940
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.195 0.465 1.536 5.226 0.000 kW
0.468 kWh
0.000 kW
2.340 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.162 0.438 1.378 4.844
09 - 202217****** IQ7+ [5] VCOP 0.000 0.190 0.485 1.622 5.468
10 - 202244****** IQ7+M [5] VCOP 0.000 0.185 0.484 1.587 5.405
11 - 202224****** IQ7+M [5] VCOP 0.000 0.185 0.467 1.573 5.324
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.160 0.455 0.769 3.971 0.000 kW
0.458 kWh
0.000 kW
1.834 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.160 0.457 0.815 4.026
14 - 202216****** IQ7+ [5] VC-- 0.000 0.161 0.464 0.825 4.088
15 - 202245****** IQ7+M [5] VCOP 0.000 0.163 0.458 0.808 4.020
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Battery History
Voltage 53.67 V Current/Power 40.77 A (2.188 kW)
Remain Capacity/Energy 357.0 Ah (18.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 59.5 % State Of Health 100.0 %
Run Time 5h 57m to full Report Date 2021-10-29 23:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.67 V Cell (MIN/MAX) 3.336 V / 3.364 V (0.028 V)
Current/Power 12.50 A (0.671 kW) Runtime 6h 28m to full
Remain Capacity/Energy 119.0 Ah (6.1 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 59.5 % State Of Health 100.0 %
Temperature 26.0 °C Cycle 46
MOSFET CFET = ON, DFET = ON Reported 2021-10-29 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.336 V 3.353 V 3.345 V 3.344 V 3.352 V 3.349 V 3.360 V 3.345 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.357 V 3.354 V 3.361 V 3.360 V 3.357 V 3.364 V 3.364 V 3.361 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.