Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.089 kW
09/22/2025 07:25 (1944 days) Production Consumption NET Usage
Now 0.225 kW 0.136 kW -0.089 kW
Today 0.055 kWh (0.007 kW) 2.960 kWh (0.398 kW) 2.905 kWh (0.391 kW)
  - This Week 21.989 kWh (16.789 kWh/day) 19.465 kWh (14.862 kWh/day) -2.524 kWh (-1.927 kWh/day)
  - This Month 454.601 kWh (21.333 kWh/day) 482.031 kWh (22.620 kWh/day) 27.430 kWh (1.287 kWh/day)
  - This Year 4.962 MWh (18.773 kWh/day) 5.653 MWh (21.387 kWh/day) 0.691 MWh (2.614 kWh/day)
Yesterday 21.934 kWh (0.914 kW) 16.505 kWh (0.688 kW) -5.429 kWh (-0.226 kW)
Last 7 Days 145.623 kWh (20.802 kWh/day) 118.817 kWh (16.973 kWh/day) -26.806 kWh (-3.829 kWh/day)
Last 30 Days 680.721 kWh (22.690 kWh/day) 660.764 kWh (22.025 kWh/day) -19.957 kWh (-0.665 kWh/day)
Last One Year 6.278 MWh (17.201 kWh/day) 7.199 MWh (19.724 kWh/day) 0.921 MWh (2.522 kWh/day)
Lifetime Since PTO 34.413 MWh (17.699 kW/day) 37.605 MWh (19.341 kW/day) 3.192 MWh (1.642 kW/day)
Lifetime Since Install 34.447 MWh 38.185 MWh 3.738 MWh
Voltage/Current 126.4 V / 0.9 A, 126.4 V / 0.9 A 126.2 V / 0.5 A, 126.6 V / 0.6 A 126.3 V / -0.4 A, 126.5 V / -0.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/06/2021 22:00 (9.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.849 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.228 1.087 1.206 6.513 0.000 kW
1.051 kWh
0.000 kW
6.306 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.221 1.015 1.120 6.027
03 - 202224****** IQ7+M [5] VCOP 0.000 0.226 1.083 1.214 6.402
04 - 202232****** IQ7+ [5] VCOP 0.000 0.225 1.035 1.168 6.188
05 - 202244****** IQ7+M [5] VCOP 0.000 0.224 1.068 1.206 6.372
06 - 202245****** IQ7+M [5] VCOP 0.000 0.221 1.018 1.162 6.175
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 1.186 1.455 7.359 0.000 kW
1.206 kWh
0.000 kW
6.032 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.033 1.280 6.677
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.318 1.601 7.781
10 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.274 1.582 7.654
11 - 202224****** IQ7+M [5] VCOP 0.000 0.273 1.222 1.515 7.520
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.127 0.590 0.638 3.977 0.000 kW
0.628 kWh
0.000 kW
2.511 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.641 0.700 4.170
14 - 202216****** IQ7+ [5] VCOP 0.000 0.128 0.647 0.705 4.221
15 - 202245****** IQ7+M [5] VCOP 0.000 0.126 0.633 0.690 4.145
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.