Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.646 kW
01/12/2026 08:56 (2056 days) Production Consumption NET Usage
Now 0.923 kW 0.277 kW -0.646 kW
Today 0.435 kWh (0.049 kW) 4.693 kWh (0.525 kW) 4.258 kWh (0.476 kW)
  - This Week 9.929 kWh (7.235 kWh/day) 20.505 kWh (14.941 kWh/day) 10.576 kWh (7.706 kWh/day)
  - This Month 85.740 kWh (7.539 kWh/day) 219.239 kWh (19.277 kWh/day) 133.499 kWh (11.738 kWh/day)
  - This Year 0.086 MWh (7.539 kWh/day) 0.219 MWh (19.277 kWh/day) 0.133 MWh (11.738 kWh/day)
Yesterday 9.494 kWh (0.396 kW) 15.812 kWh (0.659 kW) 6.318 kWh (0.263 kW)
Last 7 Days 48.464 kWh (6.923 kWh/day) 153.502 kWh (21.928 kWh/day) 105.038 kWh (15.005 kWh/day)
Last 30 Days 215.151 kWh (7.171 kWh/day) 655.728 kWh (21.857 kWh/day) 440.577 kWh (14.685 kWh/day)
Last One Year 6.095 MWh (16.700 kWh/day) 7.512 MWh (20.582 kWh/day) 1.417 MWh (3.882 kWh/day)
Lifetime Since PTO 35.651 MWh (17.337 kW/day) 39.731 MWh (19.320 kW/day) 4.079 MWh (1.984 kW/day)
Lifetime Since Install 35.685 MWh 40.311 MWh 4.625 MWh
Voltage/Current 124.6 V / 3.7 A, 124.6 V / 3.7 A 124.6 V / 1.3 A, 124.6 V / 0.9 A 124.6 V / -2.4 A, 124.6 V / -2.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/16/2022 23:11 (11.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.159 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.265 1.798 1.502 7.451 0.000 kW
1.749 kWh
0.000 kW
10.495 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.260 1.716 1.429 6.977
03 - 202224****** IQ7+M [5] VCOP 0.000 0.266 1.808 1.516 7.364
04 - 202232****** IQ7+ [5] VCOP 0.000 0.269 1.771 1.480 7.267
05 - 202244****** IQ7+M [5] VCOP 0.000 0.263 1.737 1.444 7.161
06 - 202245****** IQ7+M [5] VCOP 0.000 0.258 1.667 1.394 6.863
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.756 1.381 7.415 0.000 kW
1.889 kWh
0.000 kW
9.447 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.918 1.535 8.031
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 1.905 1.535 7.964
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.926 1.532 7.911
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.942 1.566 7.999
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.193 1.308 1.215 5.601 0.000 kW
1.304 kWh
0.000 kW
5.217 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.192 1.279 1.199 5.494
14 - 202216****** IQ7+ [5] VCOP 0.000 0.195 1.328 1.232 5.710
15 - 202245****** IQ7+M [5] VCOP 0.000 0.190 1.304 1.215 5.732
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Detail Power Per Panel

Battery History
Voltage 53.27 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 482.4 Ah (24.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 80.4 % State Of Health 100.0 %
Run Time 13d 9h 36m to empty Report Date 2022-03-16 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.31 V Cell (MIN/MAX) 3.327 V / 3.337 V (0.010 V)
Current/Power -0.47 A (-25 W) Runtime 14d 5h 24m to empty
Remain Capacity/Energy 160.8 Ah (8.2 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 80.4 % State Of Health 100.0 %
Temperature 19.0 °C Cycle 57
MOSFET CFET = ON, DFET = OFF Reported 2022-03-16 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.327 V 3.328 V 3.327 V 3.330 V 3.328 V 3.331 V 3.331 V 3.330 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.334 V 3.332 V 3.335 V 3.334 V 3.337 V 3.335 V 3.335 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.