Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.984 kW
07/14/2025 16:54 (1874 days) Production Consumption NET Usage
Now 0.801 kW 2.785 kW 1.984 kW
Today 18.165 kWh (1.072 kW) 18.163 kWh (1.072 kW) -0.002 kWh (-0.000 kW)
  - This Week 39.012 kWh (22.873 kWh/day) 52.086 kWh (30.538 kWh/day) 13.074 kWh (7.665 kWh/day)
  - This Month 336.090 kWh (24.522 kWh/day) 548.944 kWh (40.053 kWh/day) 212.854 kWh (15.531 kWh/day)
  - This Year 3.366 MWh (17.287 kWh/day) 3.676 MWh (18.881 kWh/day) 0.310 MWh (1.594 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.817 MWh (17.505 kW/day) 35.628 MWh (19.005 kW/day) 2.811 MWh (1.500 kW/day)
Lifetime Since Install 32.851 MWh 36.208 MWh 3.358 MWh
Voltage/Current 124.3 V / 3.2 A, 124.3 V / 3.2 A 124.1 V / 12.7 A, 124.6 V / 9.7 A 124.2 V / 9.5 A, 124.5 V / 6.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/23/2021 22:45 (9.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.095 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.232 0.649 0.849 4.495 0.000 kW
0.640 kWh
0.000 kW
3.839 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.226 0.615 0.813 4.244
03 - 202224****** IQ7+M [5] VCOP 0.000 0.237 0.662 0.855 4.515
04 - 202232****** IQ7+ [5] VCOP 0.000 0.230 0.647 0.820 4.385
05 - 202244****** IQ7+M [5] VCOP 0.000 0.229 0.645 0.846 4.405
06 - 202245****** IQ7+M [5] VCOP 0.000 0.226 0.622 0.815 4.295
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 0.793 1.069 5.395 0.000 kW
0.776 kWh
0.000 kW
3.879 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.293 0.714 0.969 4.905
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 0.811 1.093 5.592
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 0.792 1.075 5.425
11 - 202224****** IQ7+M [5] VCOP 0.000 0.288 0.768 1.054 5.289
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.096 0.324 0.300 2.051 0.000 kW
0.344 kWh
0.000 kW
1.378 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.113 0.351 0.358 2.265
14 - 202216****** IQ7+ [5] VCOP 0.000 0.114 0.355 0.360 2.286
15 - 202245****** IQ7+M [5] VCOP 0.000 0.107 0.348 0.351 2.238
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Battery History
Voltage 53.28 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 403.8 Ah (20.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 67.3 % State Of Health 100.0 %
Run Time 9d 8h 20m to empty Report Date 2021-12-23 23:52
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.32 V Cell (MIN/MAX) 3.294 V / 3.339 V (0.045 V)
Current/Power -0.58 A (-30 W) Runtime 9d 16h 4m to empty
Remain Capacity/Energy 134.6 Ah (6.9 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 67.3 % State Of Health 100.0 %
Temperature 19.0 °C Cycle 50
MOSFET CFET = ON, DFET = ON Reported 2021-12-23 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.294 V 3.330 V 3.331 V 3.331 V 3.332 V 3.333 V 3.333 V 3.334 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.335 V 3.335 V 3.336 V 3.337 V 3.337 V 3.338 V 3.339 V 3.338 V
pack voltage and current cell voltages
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.