Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.135 kW
07/14/2025 11:44 (1874 days) Production Consumption NET Usage
Now 1.501 kW 0.366 kW -1.135 kW
Today 6.757 kWh (0.574 kW) 9.406 kWh (0.799 kW) 2.649 kWh (0.225 kW)
  - This Week 27.604 kWh (18.525 kWh/day) 43.329 kWh (29.079 kWh/day) 15.725 kWh (10.553 kWh/day)
  - This Month 324.682 kWh (24.069 kWh/day) 540.187 kWh (40.044 kWh/day) 215.505 kWh (15.975 kWh/day)
  - This Year 3.354 MWh (17.247 kWh/day) 3.667 MWh (18.857 kWh/day) 0.313 MWh (1.610 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.805 MWh (17.501 kW/day) 35.619 MWh (19.002 kW/day) 2.814 MWh (1.501 kW/day)
Lifetime Since Install 32.839 MWh 36.199 MWh 3.360 MWh
Voltage/Current 124.4 V / 6.0 A, 124.4 V / 6.0 A 124.4 V / 1.6 A, 124.2 V / 1.4 A 124.4 V / -4.5 A, 124.3 V / -4.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/27/2021 22:20 (8.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.487 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.180 0.980 4.604 0.000 kW
0.169 kWh
0.000 kW
1.014 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.190 0.163 0.940 4.365
03 - 202224****** IQ7+M [5] VCOP 0.000 0.195 0.179 0.986 4.643
04 - 202232****** IQ7+ [5] VCOP 0.000 0.202 0.166 0.963 4.533
05 - 202244****** IQ7+M [5] VCOP 0.000 0.192 0.166 0.984 4.551
06 - 202245****** IQ7+M [5] VCOP 0.000 0.200 0.161 0.953 4.427
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.224 0.178 1.219 5.598 0.000 kW
0.174 kWh
0.000 kW
0.868 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.220 0.176 1.057 5.044
09 - 202217****** IQ7+ [5] VCOP 0.000 0.222 0.178 1.282 5.813
10 - 202244****** IQ7+M [5] VCOP 0.000 0.224 0.161 1.273 5.680
11 - 202224****** IQ7+M [5] VCOP 0.000 0.223 0.177 1.182 5.466
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.092 0.148 0.290 1.923 0.000 kW
0.151 kWh
0.000 kW
0.605 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.089 0.151 0.360 2.172
14 - 202216****** IQ7+ [5] VCOP 0.000 0.094 0.154 0.359 2.188
15 - 202245****** IQ7+M [5] VCOP 0.000 0.097 0.151 0.350 2.139
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Detail Power Per Panel

Battery History
Voltage 52.72 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 337.8 Ah (17.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 56.3 % State Of Health 100.0 %
Run Time 15d 15h 20m to empty Report Date 2021-12-27 23:52
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.