| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.480 kW | |||
|---|---|---|---|
| 09/28/2026 14:48 (2315 days) | Production | Consumption | NET Usage |
| Now | 0.829 kW | 0.349 kW | -0.480 kW |
| Today | 6.194 kWh (0.418 kW) | 5.840 kWh (0.394 kW) | -0.354 kWh (-0.024 kW) |
| - This Week | 10.915 kWh (6.748 kWh/day) | 17.402 kWh (10.758 kWh/day) | 6.487 kWh (4.010 kWh/day) |
| - This Month | 482.825 kWh (17.483 kWh/day) | 466.745 kWh (16.900 kWh/day) | -16.080 kWh (-0.582 kWh/day) |
| - This Year | 5.773 MWh (21.333 kWh/day) | 5.627 MWh (20.795 kWh/day) | -0.146 MWh (-0.539 kWh/day) |
| Yesterday | 4.721 kWh (0.197 kW) | 11.562 kWh (0.482 kW) | 6.841 kWh (0.285 kW) |
| Last 7 Days | 91.741 kWh (13.106 kWh/day) | 102.452 kWh (14.636 kWh/day) | 10.711 kWh (1.530 kWh/day) |
| Last 30 Days (08/29/2026) | 541.338 kWh (18.045 kWh/day) | 581.919 kWh (19.397 kWh/day) | 40.581 kWh (1.353 kWh/day) |
| Last One Year | 6.827 MWh (18.704 kWh/day) | 7.378 MWh (20.213 kWh/day) | 0.551 MWh (1.509 kWh/day) |
| Lifetime Since PTO | 41.339 MWh (17.852 kW/day) | 45.138 MWh (19.493 kW/day) | 3.799 MWh (1.641 kW/day) |
| Lifetime Since Install | 41.373 MWh | 45.718 MWh | 4.345 MWh |
| Voltage/Current | 124.7 V / 3.3 A, 124.7 V / 3.3 A | 124.5 V / 2.2 A, 124.9 V / 0.6 A | 124.6 V / -1.1 A, 124.8 V / -2.8 A |
|
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 05/12/2023 23:12 (13.8 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 29.892 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.295 | 2.002 | 2.131 | 14.216 | 0.000 kW 1.894 kWh |
0.000 kW 11.364 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.281 | 1.859 | 1.991 | 13.341 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.287 | 1.912 | 2.053 | 13.775 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.294 | 1.951 | 2.092 | 14.007 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.282 | 1.732 | 1.885 | 12.623 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.290 | 1.909 | 2.045 | 13.615 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.293 | 1.813 | 1.991 | 13.225 | 0.000 kW 1.809 kWh |
0.000 kW 9.043 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.294 | 1.771 | 2.010 | 13.086 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.293 | 1.779 | 2.009 | 13.141 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.291 | 1.823 | 1.998 | 13.274 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.294 | 1.856 | 2.031 | 13.495 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.253 | 1.871 | 1.917 | 13.246 | 0.000 kW 1.918 kWh |
0.000 kW 7.672 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.259 | 1.906 | 1.922 | 13.330 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.260 | 1.948 | 1.995 | 13.850 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.259 | 1.946 | 1.998 | 13.847 | |||
| yard | 16 - 122344****** | IQ7AS | [4] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| battery | 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.230 | 1.813 | 1.826 | 11.583 | 0.000 kW 0.906 kWh |
0.000 kW 1.813 kWh |
| 18 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.16 V | Current/Power | -8.64 A (-0.459 kW) |
| Remain Capacity/Energy | 465.0 Ah (23.8 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 77.5 % | State Of Health | 100.0 % |
| Run Time | 2d 5h 49m to empty | Report Date | 2023-05-12 23:59 |
|
|
|||
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.319 V / 3.330 V (0.011 V) |
|---|---|---|---|
| Current/Power | -1.80 A (-95 W) | Runtime | 3d 14h 6m to empty |
| Remain Capacity/Energy | 155.0 Ah (7.9 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 77.5 % | State Of Health | 100.0 % |
| Temperature | 21.0 °C | Cycle | 100 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-12 23:59 |
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.33 A (-70 W) | Runtime | 2d 20h 23m to empty |
| Remain Capacity/Energy | 90.9 Ah (4.7 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 91.4 % | State Of Health | 99.5 % |
| Temperature | 21.3 °C | Cycle | 44 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-12 23:59 |
| Voltage | 53.19 V | Cell (MIN/MAX) | 3.323 V / 3.324 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.50 A (-79 W) | Runtime | 2d 12h 9m to empty |
| Remain Capacity/Energy | 90.2 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.7 % | State Of Health | 99.5 % |
| Temperature | 22.5 °C | Cycle | 46 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-12 23:59 |
| Voltage | 53.14 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.48 A (-78 W) | Runtime | 2d 12h 47m to empty |
| Remain Capacity/Energy | 89.7 Ah (4.6 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 90.1 % | State Of Health | 99.5 % |
| Temperature | 23.1 °C | Cycle | 47 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-12 23:59 |
| Voltage | 53.15 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.43 A (-75 W) | Runtime | 2d 15h 9m to empty |
| Remain Capacity/Energy | 90.2 Ah (4.6 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 90.9 % | State Of Health | 99.2 % |
| Temperature | 21.6 °C | Cycle | 46 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-12 23:59 |