| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.365 kW | |||
|---|---|---|---|
| 04/04/2026 00:50 (2138 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.365 kW | 0.365 kW |
| Today | 0.000 kWh (0.000 kW) | 0.676 kWh (0.783 kW) | 0.676 kWh (0.783 kW) |
| - This Week | 107.693 kWh (17.843 kWh/day) | 101.743 kWh (16.857 kWh/day) | -5.950 kWh (-0.986 kWh/day) |
| - This Month | 35.328 kWh (11.638 kWh/day) | 46.100 kWh (15.186 kWh/day) | 10.772 kWh (3.549 kWh/day) |
| - This Year | 1.265 MWh (13.594 kWh/day) | 1.611 MWh (17.321 kWh/day) | 0.347 MWh (3.726 kWh/day) |
| Yesterday | 18.529 kWh (0.772 kW) | 13.745 kWh (0.573 kW) | -4.784 kWh (-0.199 kW) |
| Last 7 Days | 135.241 kWh (19.320 kWh/day) | 116.535 kWh (16.648 kWh/day) | -18.706 kWh (-2.672 kWh/day) |
| Last 30 Days (03/05/2026) | 549.126 kWh (18.304 kWh/day) | 454.383 kWh (15.146 kWh/day) | -94.743 kWh (-3.158 kWh/day) |
| Last One Year | 6.100 MWh (16.713 kWh/day) | 7.838 MWh (21.473 kWh/day) | 1.738 MWh (4.760 kWh/day) |
| Lifetime Since PTO | 36.830 MWh (17.226 kW/day) | 41.122 MWh (19.234 kW/day) | 4.292 MWh (2.007 kW/day) |
| Lifetime Since Install | 36.864 MWh | 41.702 MWh | 4.838 MWh |
| Voltage/Current | 124.7 V / 0.0 A, 124.7 V / 0.0 A | 124.4 V / 2.3 A, 124.7 V / 0.6 A | 124.5 V / 2.3 A, 124.7 V / 0.6 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 03/14/2023 23:59 (11.9 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 10.962 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.146 | 0.584 | 0.267 | 6.833 | 0.000 kW 0.555 kWh |
0.000 kW 3.328 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.141 | 0.535 | 0.263 | 6.525 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.154 | 0.579 | 0.266 | 6.758 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.151 | 0.573 | 0.255 | 6.652 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.143 | 0.524 | 0.257 | 6.410 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.140 | 0.534 | 0.260 | 6.453 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.137 | 0.522 | 0.255 | 6.599 | 0.000 kW 0.535 kWh |
0.000 kW 2.675 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.140 | 0.535 | 0.263 | 6.893 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.139 | 0.537 | 0.262 | 7.034 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.140 | 0.539 | 0.263 | 7.057 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.140 | 0.542 | 0.237 | 6.957 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.131 | 0.501 | 0.249 | 4.992 | 0.000 kW 0.557 kWh |
0.000 kW 2.226 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.142 | 0.548 | 0.245 | 5.151 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.149 | 0.589 | 0.302 | 5.425 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.146 | 0.588 | 0.301 | 5.352 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 1.366 kWh |
0.000 kW 2.732 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.237 | 2.732 | 2.281 | 4.869 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.56 V | Current/Power | -0.90 A (-47 W) |
| Remain Capacity/Energy | 328.5 Ah (16.8 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 54.8 % | State Of Health | 100.0 % |
| Run Time | 15d 5h 0m to empty | Report Date | 2023-03-14 23:54 |
|
|||
| Voltage | 52.56 V | Cell (MIN/MAX) | 3.279 V / 3.290 V (0.011 V) |
|---|---|---|---|
| Current/Power | -0.34 A (-18 W) | Runtime | 13d 5h 23m to empty |
| Remain Capacity/Energy | 109.5 Ah (5.6 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 54.8 % | State Of Health | 100.0 % |
| Temperature | 16.5 °C | Cycle | 91 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-14 23:54 |
| Voltage | 52.56 V | Cell (MIN/MAX) | 3.284 V / 3.286 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 92.1 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 92.1 % | State Of Health | 100.0 % |
| Temperature | 17.2 °C | Cycle | 36 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-14 23:56 |
| Voltage | 52.58 V | Cell (MIN/MAX) | 3.284 V / 3.287 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 91.0 Ah (4.7 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 91.0 % | State Of Health | 100.0 % |
| Temperature | 18.3 °C | Cycle | 37 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-14 23:56 |
| Voltage | 52.56 V | Cell (MIN/MAX) | 3.284 V / 3.286 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 89.7 Ah (4.6 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 89.7 % | State Of Health | 100.0 % |
| Temperature | 19.4 °C | Cycle | 38 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-14 23:55 |
| Voltage | 52.54 V | Cell (MIN/MAX) | 3.283 V / 3.284 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 91.6 Ah (4.7 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 91.9 % | State Of Health | 99.7 % |
| Temperature | 17.9 °C | Cycle | 38 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-03-14 23:56 |