| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.722 kW | |||
|---|---|---|---|
| 04/03/2026 22:55 (2137 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.722 kW | 0.722 kW |
| Today | 18.529 kWh (0.808 kW) | 13.053 kWh (0.569 kW) | -5.476 kWh (-0.239 kW) |
| - This Week | 107.693 kWh (18.083 kWh/day) | 100.375 kWh (16.854 kWh/day) | -7.318 kWh (-1.229 kWh/day) |
| - This Month | 35.328 kWh (11.953 kWh/day) | 44.732 kWh (15.135 kWh/day) | 9.404 kWh (3.182 kWh/day) |
| - This Year | 1.265 MWh (13.606 kWh/day) | 1.610 MWh (17.321 kWh/day) | 0.345 MWh (3.715 kWh/day) |
| Yesterday | 4.090 kWh (0.170 kW) | 14.761 kWh (0.615 kW) | 10.671 kWh (0.445 kW) |
| Last 7 Days | 135.241 kWh (19.320 kWh/day) | 115.869 kWh (16.553 kWh/day) | -19.372 kWh (-2.767 kWh/day) |
| Last 30 Days (03/04/2026) | 549.714 kWh (18.324 kWh/day) | 453.990 kWh (15.133 kWh/day) | -95.724 kWh (-3.191 kWh/day) |
| Last One Year | 6.100 MWh (16.713 kWh/day) | 7.838 MWh (21.473 kWh/day) | 1.738 MWh (4.760 kWh/day) |
| Lifetime Since PTO | 36.830 MWh (17.227 kW/day) | 41.121 MWh (19.234 kW/day) | 4.290 MWh (2.007 kW/day) |
| Lifetime Since Install | 36.864 MWh | 41.701 MWh | 4.836 MWh |
| Voltage/Current | 124.9 V / 0.0 A, 124.9 V / 0.0 A | 124.9 V / 2.2 A, 124.9 V / 3.6 A | 124.9 V / 2.2 A, 124.9 V / 3.6 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 04/17/2023 23:42 (12.3 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 15.037 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.302 | 0.969 | 0.808 | 11.682 | 0.000 kW 0.945 kWh |
0.000 kW 5.668 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.304 | 0.925 | 0.765 | 11.114 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.305 | 0.957 | 0.802 | 11.558 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.304 | 0.958 | 0.803 | 11.709 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.304 | 0.921 | 0.746 | 10.736 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.303 | 0.938 | 0.774 | 11.096 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.302 | 1.017 | 0.751 | 11.314 | 0.000 kW 1.015 kWh |
0.000 kW 5.073 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.302 | 1.006 | 0.722 | 11.391 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.303 | 1.006 | 0.718 | 11.318 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.305 | 1.018 | 0.756 | 11.538 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.302 | 1.026 | 0.770 | 11.752 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.264 | 0.647 | 0.715 | 9.644 | 0.000 kW 0.679 kWh |
0.000 kW 2.715 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.273 | 0.658 | 0.752 | 9.838 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.277 | 0.707 | 0.785 | 10.216 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.274 | 0.703 | 0.787 | 10.203 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.790 kWh |
0.000 kW 1.581 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.236 | 1.581 | 1.542 | 11.269 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 52.70 V | Current/Power | -1.29 A (-67 W) |
| Remain Capacity/Energy | 222.9 Ah (11.4 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 37.2 % | State Of Health | 100.0 % |
| Run Time | 7d 4h 47m to empty | Report Date | 2023-04-17 23:56 |
|
|||
| Voltage | 52.71 V | Cell (MIN/MAX) | 3.287 V / 3.300 V (0.013 V) |
|---|---|---|---|
| Current/Power | -0.43 A (-22 W) | Runtime | 7d 4h 47m to empty |
| Remain Capacity/Energy | 74.3 Ah (3.8 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 37.1 % | State Of Health | 100.0 % |
| Temperature | 21.0 °C | Cycle | 96 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-04-17 23:56 |
| Voltage | 52.69 V | Cell (MIN/MAX) | 3.292 V / 3.293 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 56.4 Ah (2.9 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 56.7 % | State Of Health | 99.5 % |
| Temperature | 21.1 °C | Cycle | 41 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-04-17 23:55 |
| Voltage | 52.72 V | Cell (MIN/MAX) | 3.294 V / 3.296 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 54.9 Ah (2.8 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 55.2 % | State Of Health | 99.5 % |
| Temperature | 22.6 °C | Cycle | 43 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-04-17 23:55 |
| Voltage | 52.70 V | Cell (MIN/MAX) | 3.293 V / 3.293 V (0.000 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 55.3 Ah (2.8 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 55.6 % | State Of Health | 99.5 % |
| Temperature | 23.3 °C | Cycle | 44 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-04-17 23:55 |
| Voltage | 52.69 V | Cell (MIN/MAX) | 3.292 V / 3.293 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 54.9 Ah (2.8 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 55.4 % | State Of Health | 99.2 % |
| Temperature | 21.5 °C | Cycle | 43 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-04-17 23:56 |