| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.617 kW | |||
|---|---|---|---|
| 04/03/2026 20:17 (2137 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.617 kW | 0.617 kW |
| Today | 18.529 kWh (0.912 kW) | 10.953 kWh (0.539 kW) | -7.576 kWh (-0.373 kW) |
| - This Week | 107.693 kWh (18.423 kWh/day) | 98.275 kWh (16.812 kWh/day) | -9.418 kWh (-1.611 kWh/day) |
| - This Month | 35.328 kWh (12.415 kWh/day) | 42.632 kWh (14.981 kWh/day) | 7.304 kWh (2.567 kWh/day) |
| - This Year | 1.265 MWh (13.622 kWh/day) | 1.608 MWh (17.319 kWh/day) | 0.343 MWh (3.697 kWh/day) |
| Yesterday | 4.090 kWh (0.170 kW) | 14.761 kWh (0.615 kW) | 10.671 kWh (0.445 kW) |
| Last 7 Days | 135.241 kWh (19.320 kWh/day) | 115.808 kWh (16.544 kWh/day) | -19.433 kWh (-2.776 kWh/day) |
| Last 30 Days (03/04/2026) | 550.554 kWh (18.352 kWh/day) | 454.145 kWh (15.138 kWh/day) | -96.409 kWh (-3.214 kWh/day) |
| Last One Year | 6.100 MWh (16.713 kWh/day) | 7.838 MWh (21.473 kWh/day) | 1.738 MWh (4.761 kWh/day) |
| Lifetime Since PTO | 36.830 MWh (17.228 kW/day) | 41.119 MWh (19.234 kW/day) | 4.288 MWh (2.006 kW/day) |
| Lifetime Since Install | 36.864 MWh | 41.699 MWh | 4.834 MWh |
| Voltage/Current | 124.2 V / 0.0 A, 124.2 V / 0.0 A | 124.0 V / 4.3 A, 124.3 V / 0.6 A | 124.1 V / 4.3 A, 124.3 V / 0.6 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 05/04/2023 22:13 (13.3 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 12.686 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.287 | 0.786 | 0.984 | 5.394 | 0.000 kW 0.761 kWh |
0.000 kW 4.567 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.273 | 0.741 | 0.929 | 5.094 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.284 | 0.779 | 0.970 | 5.320 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.289 | 0.777 | 0.972 | 5.358 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.278 | 0.734 | 0.901 | 4.877 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.279 | 0.750 | 0.941 | 5.140 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.297 | 0.740 | 0.875 | 4.958 | 0.000 kW 0.748 kWh |
0.000 kW 3.739 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.748 | 0.884 | 4.993 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.296 | 0.749 | 0.888 | 5.014 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.751 | 0.890 | 5.049 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.296 | 0.751 | 0.897 | 5.086 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.206 | 0.659 | 0.927 | 4.948 | 0.000 kW 0.704 kWh |
0.000 kW 2.817 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.219 | 0.691 | 0.975 | 5.115 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.269 | 0.739 | 1.009 | 5.377 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.235 | 0.727 | 1.013 | 5.384 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.781 kWh |
0.000 kW 1.562 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.230 | 1.562 | 1.568 | 7.373 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.31 V | Current/Power | -1.68 A (-89 W) |
| Remain Capacity/Energy | 413.4 Ah (21.2 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 68.9 % | State Of Health | 100.0 % |
| Run Time | 10d 6h 4m to empty | Report Date | 2023-05-04 23:57 |
|
|||
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.329 V / 3.338 V (0.009 V) |
|---|---|---|---|
| Current/Power | -0.50 A (-26 W) | Runtime | 11d 11h 36m to empty |
| Remain Capacity/Energy | 137.8 Ah (7.1 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 68.9 % | State Of Health | 100.0 % |
| Temperature | 20.0 °C | Cycle | 98 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-04 23:57 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.331 V / 3.332 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 20.6 °C | Cycle | 43 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-04 23:58 |
| Voltage | 53.34 V | Cell (MIN/MAX) | 3.332 V / 3.334 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 21.7 °C | Cycle | 45 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-04 23:58 |
| Voltage | 53.29 V | Cell (MIN/MAX) | 3.329 V / 3.331 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 22.5 °C | Cycle | 46 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-04 23:58 |
| Voltage | 53.30 V | Cell (MIN/MAX) | 3.330 V / 3.332 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 98.7 Ah (5.1 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.2 % |
| Temperature | 21.1 °C | Cycle | 45 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2023-05-04 23:58 |