Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.117 kW
05/22/2026 18:12 (2186 days) Production Consumption NET Usage
Now 0.433 kW 0.316 kW -0.117 kW
Today 29.215 kWh (1.604 kW) 2.464 kWh (0.135 kW) -26.751 kWh (-1.468 kW)
  - This Week 154.992 kWh (26.912 kWh/day) 146.628 kWh (25.459 kWh/day) -8.364 kWh (-1.452 kWh/day)
  - This Month 556.808 kWh (25.590 kWh/day) 346.350 kWh (15.918 kWh/day) -210.458 kWh (-9.672 kWh/day)
  - This Year 2.510 MWh (17.705 kWh/day) 2.406 MWh (16.973 kWh/day) -0.104 MWh (-0.732 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.469 kWh (26.924 kWh/day) 156.832 kWh (22.405 kWh/day) -31.637 kWh (-4.520 kWh/day)
Last 30 Days (04/22/2026) 720.843 kWh (24.028 kWh/day) 419.633 kWh (13.988 kWh/day) -301.210 kWh (-10.040 kWh/day)
Last One Year 6.391 MWh (17.511 kWh/day) 7.791 MWh (21.346 kWh/day) 1.400 MWh (3.835 kWh/day)
Lifetime Since PTO 38.076 MWh (17.412 kW/day) 41.917 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.109 MWh 42.497 MWh 4.387 MWh
Voltage/Current 249.6 V / 1.7 A 249.6 V / 1.3 A 249.6 V / -0.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/28/2026 23:00 (18.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.096 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.257 1.608 1.705 4.477 0.000 kW
1.575 kWh
0.000 kW
9.450 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.248 1.540 1.626 4.270
03 - 202224****** IQ7+M [5] VCOP 0.000 0.257 1.600 1.684 4.453
04 - 202232****** IQ7+ [5] VCOP 0.000 0.258 1.587 1.664 4.393
05 - 202244****** IQ7+M [5] VCOP 0.000 0.250 1.547 1.618 4.393
06 - 202245****** IQ7+M [5] VCOP 0.000 0.252 1.568 1.647 4.511
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 1.751 1.719 4.803 0.000 kW
1.838 kWh
0.000 kW
9.192 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.853 1.873 5.138
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.855 1.931 5.212
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.858 1.942 5.228
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.875 1.936 5.249
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.165 0.897 0.987 2.619 0.000 kW
0.961 kWh
0.000 kW
3.843 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.169 0.965 1.056 2.559
14 - 202216****** IQ7+ [5] VCOP 0.000 0.174 0.992 1.090 2.620
15 - 202245****** IQ7+M [5] VCOP 0.000 0.172 0.989 1.085 2.726
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.322 2.786 4.749 4.977 0.000 kW
1.805 kWh
0.000 kW
3.610 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.160 0.824 0.909 3.391
Panel Layout Each Group Production

Charger History
Voltage PV 1.61 V Voltage Charge 53.07 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.4 °C / 21.6 °C Flags 00/00/00 Energy Today 9.721 kWh @ 2026-02-28 23:56
voltage in/out power and energy

Battery History
Voltage 53.26 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 429.0 Ah (22.0 kWh) Full Capacity/Energy 548.1 Ah (28.1 kWh)
State Of Charge 78.3 % State Of Health 91.4 %
Run Time 11d 22h 0m to empty Report Date 2026-02-28 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.