Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.309 kW
05/23/2026 13:23 (2187 days) Production Consumption NET Usage
Now 0.375 kW 0.066 kW -0.309 kW
Today 3.423 kWh (0.255 kW) 3.154 kWh (0.235 kW) -0.269 kWh (-0.020 kW)
  - This Week 158.795 kWh (24.210 kWh/day) 152.423 kWh (23.239 kWh/day) -6.372 kWh (-0.971 kWh/day)
  - This Month 560.611 kWh (24.851 kWh/day) 352.145 kWh (15.610 kWh/day) -208.466 kWh (-9.241 kWh/day)
  - This Year 2.514 MWh (17.632 kWh/day) 2.412 MWh (16.918 kWh/day) -0.102 MWh (-0.714 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 174.986 kWh (24.998 kWh/day) 157.659 kWh (22.523 kWh/day) -17.327 kWh (-2.475 kWh/day)
Last 30 Days (04/23/2026) 709.019 kWh (23.634 kWh/day) 420.284 kWh (14.009 kWh/day) -288.735 kWh (-9.625 kWh/day)
Last One Year 6.390 MWh (17.507 kWh/day) 7.786 MWh (21.332 kWh/day) 1.396 MWh (3.825 kWh/day)
Lifetime Since PTO 38.079 MWh (17.407 kW/day) 41.923 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.113 MWh 42.503 MWh 4.389 MWh
Voltage/Current 249.7 V / 1.5 A 249.5 V / 0.3 A 249.6 V / -1.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/07/2024 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 29.763 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.738 1.261 6.398 0.000 kW
1.703 kWh
0.000 kW
10.217 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.675 1.223 6.128
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.719 1.261 6.379
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.721 1.250 6.371
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.669 1.200 5.914
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.696 1.226 6.087
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.852 1.206 6.025 0.000 kW
1.812 kWh
0.000 kW
9.062 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.785 1.208 6.124
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.740 1.191 6.087
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.823 1.225 6.151
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.863 1.241 6.209
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.206 1.137 5.517 0.000 kW
1.247 kWh
0.000 kW
4.987 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.284 1.207 1.188 5.749
14 - 202216****** IQ7+ [5] VCOP 0.000 0.267 1.295 1.223 5.996
15 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.280 1.223 5.961
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.748 kWh
0.230 kW
5.497 kWh
17 - 122214****** IQ7PD [4] VCOP 0.230 0.230 5.497 5.477 32.944
Panel Layout Each Group Production

Battery History
Voltage 52.54 V Current/Power -6.29 A (-0.330 kW)
Remain Capacity/Energy 211.6 Ah (10.8 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.7 % State Of Health 98.9 %
Run Time 1d 9h 38m to empty Report Date 2024-04-07 23:58
voltag, current for each battery pack voltage, current, and SOC