Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.025 kW
04/07/2026 04:23 (2141 days) Production Consumption NET Usage
Now 0.317 kW 0.342 kW 0.025 kW
Today 1.391 kWh (0.317 kW) 2.172 kWh (0.495 kW) 0.781 kWh (0.178 kW)
  - This Week 37.309 kWh (17.091 kWh/day) 26.873 kWh (12.311 kWh/day) -10.436 kWh (-4.781 kWh/day)
  - This Month 89.914 kWh (14.542 kWh/day) 87.932 kWh (14.222 kWh/day) -1.982 kWh (-0.321 kWh/day)
  - This Year 1.319 MWh (13.717 kWh/day) 1.653 MWh (17.189 kWh/day) 0.334 MWh (3.472 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 107.996 kWh (15.428 kWh/day) 101.208 kWh (14.458 kWh/day) -6.788 kWh (-0.970 kWh/day)
Last 30 Days (03/08/2026) 591.703 kWh (19.723 kWh/day) 445.619 kWh (14.854 kWh/day) -146.084 kWh (-4.869 kWh/day)
Last One Year 6.129 MWh (16.791 kWh/day) 7.831 MWh (21.455 kWh/day) 1.702 MWh (4.664 kWh/day)
Lifetime Since PTO 36.885 MWh (17.226 kW/day) 41.164 MWh (19.225 kW/day) 4.279 MWh (1.998 kW/day)
Lifetime Since Install 36.919 MWh 41.744 MWh 4.825 MWh
Voltage/Current 250.0 V / 1.3 A 250.1 V / 1.4 A 250.0 V / 0.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/07/2024 23:59 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 37.238 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.292 2.260 1.252 9.032 0.000 kW
2.141 kWh
0.000 kW
12.848 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.277 2.094 1.193 8.586
03 - 202224****** IQ7+M [0] ---- 0.000 0.287 2.173 1.237 8.905
04 - 202232****** IQ7+ [0] ---- 0.000 0.290 2.230 1.236 8.990
05 - 202244****** IQ7+M [0] ---- 0.000 0.277 1.955 1.176 8.326
06 - 202245****** IQ7+M [0] ---- 0.000 0.284 2.137 1.207 8.717
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 2.133 1.209 8.676 0.000 kW
2.113 kWh
0.000 kW
10.566 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 2.085 1.211 8.538
09 - 202217****** IQ7+ [0] ---- 0.000 0.289 2.073 1.205 8.506
10 - 202244****** IQ7+M [0] ---- 0.000 0.287 2.111 1.204 8.612
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 2.165 1.223 8.797
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.244 2.029 1.020 7.514 0.000 kW
2.082 kWh
0.000 kW
8.327 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.251 2.021 1.057 7.663
14 - 202216****** IQ7+ [0] ---- 0.000 0.254 2.141 1.108 8.114
15 - 202245****** IQ7+M [0] ---- 0.000 0.254 2.136 1.104 8.095
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.748 kWh
0.230 kW
5.496 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.231 5.496 5.515 32.940
Panel Layout Each Group Production

Battery History
Voltage 53.13 V Current/Power -6.24 A (-0.332 kW)
Remain Capacity/Energy 393.0 Ah (20.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 66.3 % State Of Health 98.9 %
Run Time 2d 14h 59m to empty Report Date 2024-05-07 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.