Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.582 kW
05/23/2026 10:56 (2187 days) Production Consumption NET Usage
Now 0.912 kW 1.494 kW 0.582 kW
Today 1.744 kWh (0.159 kW) 1.040 kWh (0.095 kW) -0.704 kWh (-0.064 kW)
  - This Week 157.116 kWh (24.334 kWh/day) 150.309 kWh (23.280 kWh/day) -6.807 kWh (-1.054 kWh/day)
  - This Month 558.932 kWh (24.890 kWh/day) 350.031 kWh (15.587 kWh/day) -208.901 kWh (-9.303 kWh/day)
  - This Year 2.512 MWh (17.633 kWh/day) 2.410 MWh (16.916 kWh/day) -0.102 MWh (-0.718 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 182.961 kWh (26.137 kWh/day) 155.985 kWh (22.284 kWh/day) -26.976 kWh (-3.854 kWh/day)
Last 30 Days (04/23/2026) 716.517 kWh (23.884 kWh/day) 419.416 kWh (13.981 kWh/day) -297.101 kWh (-9.903 kWh/day)
Last One Year 6.391 MWh (17.509 kWh/day) 7.785 MWh (21.328 kWh/day) 1.394 MWh (3.820 kWh/day)
Lifetime Since PTO 38.078 MWh (17.407 kW/day) 41.921 MWh (19.164 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.112 MWh 42.500 MWh 4.389 MWh
Voltage/Current 248.1 V / 3.7 A 248.1 V / 6.0 A 248.1 V / 2.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/07/2024 23:59 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 29.051 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.689 1.905 12.995 0.000 kW
1.634 kWh
0.000 kW
9.805 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.284 1.606 1.803 12.226
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.656 1.837 12.493
04 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.674 1.872 12.728
05 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.549 1.665 11.250
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.633 1.845 12.537
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.281 1.590 1.764 11.850 0.000 kW
1.573 kWh
0.000 kW
7.866 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.276 1.525 1.685 11.527
09 - 202217****** IQ7+ [5] VCOP 0.000 0.282 1.542 1.711 11.621
10 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.586 1.757 11.810
11 - 202224****** IQ7+M [5] VCOP 0.000 0.274 1.623 1.797 12.043
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.276 1.408 1.638 11.945 0.000 kW
1.467 kWh
0.000 kW
5.870 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.280 1.441 1.633 12.102
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 1.511 1.746 12.732
15 - 202245****** IQ7+M [5] VCOP 0.000 0.271 1.510 1.744 12.727
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.755 kWh
0.230 kW
5.510 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.231 5.510 5.495 32.925
Panel Layout Each Group Production

Battery History
Voltage 52.64 V Current/Power -6.19 A (-0.326 kW)
Remain Capacity/Energy 342.9 Ah (17.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.8 % State Of Health 98.9 %
Run Time 2d 7h 23m to empty Report Date 2024-07-07 23:55
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.