Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.250 kW
05/23/2026 08:42 (2187 days) Production Consumption NET Usage
Now 0.315 kW 0.065 kW -0.250 kW
Today 0.581 kWh (0.067 kW) 0.579 kWh (0.066 kW) -0.002 kWh (-0.000 kW)
  - This Week 155.953 kWh (24.508 kWh/day) 149.848 kWh (23.548 kWh/day) -6.105 kWh (-0.959 kWh/day)
  - This Month 557.769 kWh (24.942 kWh/day) 349.570 kWh (15.632 kWh/day) -208.199 kWh (-9.310 kWh/day)
  - This Year 2.511 MWh (17.637 kWh/day) 2.409 MWh (16.924 kWh/day) -0.102 MWh (-0.713 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 187.316 kWh (26.759 kWh/day) 156.122 kWh (22.303 kWh/day) -31.194 kWh (-4.456 kWh/day)
Last 30 Days (04/23/2026) 720.459 kWh (24.015 kWh/day) 419.647 kWh (13.988 kWh/day) -300.812 kWh (-10.027 kWh/day)
Last One Year 6.391 MWh (17.511 kWh/day) 7.785 MWh (21.330 kWh/day) 1.394 MWh (3.819 kWh/day)
Lifetime Since PTO 38.076 MWh (17.407 kW/day) 41.920 MWh (19.165 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 248.3 V / 1.3 A 248.2 V / 0.3 A 248.2 V / -1.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/02/2024 23:54 (23.8 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 19.418 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.249 0.980 1.195 4.187 0.000 kW
0.951 kWh
0.000 kW
5.706 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.241 0.933 1.133 3.961
03 - 202224****** IQ7+M [5] VCOP 0.000 0.243 0.967 1.179 4.136
04 - 202232****** IQ7+ [5] VCOP 0.000 0.246 0.969 1.189 4.156
05 - 202244****** IQ7+M [5] VCOP 0.000 0.242 0.915 1.125 3.915
06 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.943 1.156 4.029
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.253 0.927 1.254 4.181 0.000 kW
0.954 kWh
0.000 kW
4.770 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.254 0.963 1.284 4.258
09 - 202217****** IQ7+ [5] VCOP 0.000 0.269 0.959 1.264 4.211
10 - 202244****** IQ7+M [5] VCOP 0.000 0.264 0.957 1.275 4.227
11 - 202224****** IQ7+M [5] VCOP 0.000 0.268 0.963 1.295 4.262
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.200 0.816 0.773 3.060 0.000 kW
0.866 kWh
0.000 kW
3.462 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.209 0.859 0.819 3.258
14 - 202216****** IQ7+ [5] VCOP 0.000 0.195 0.894 0.860 3.441
15 - 202245****** IQ7+M [5] VCOP 0.000 0.199 0.893 0.857 3.423
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.740 kWh
0.230 kW
5.479 kWh
17 - 122214****** IQ7PD [4] VCOP 0.230 0.230 5.479 5.518 5.901
Panel Layout Each Group Production

Charger History
Voltage PV 0.55 V Voltage Charge 52.18 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 28.8 °C / 26.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2024-10-02 23:57
voltage in/out power and energy

Battery History
Voltage 52.44 V Current/Power -5.61 A (-0.294 kW)
Remain Capacity/Energy 252.9 Ah (12.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 42.6 % State Of Health 98.9 %
Run Time 1d 21h 4m to empty Report Date 2024-10-02 23:55
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.