Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 5.539 kW
04/06/2026 14:35 (2140 days) Production Consumption NET Usage
Now 4.054 kW -1.485 kW -5.539 kW
Today 20.418 kWh (1.398 kW) 3.223 kWh (0.221 kW) -17.195 kWh (-1.177 kW)
  - This Week 24.879 kWh (15.472 kWh/day) 22.828 kWh (14.196 kWh/day) -2.051 kWh (-1.275 kWh/day)
  - This Month 77.484 kWh (13.816 kWh/day) 83.887 kWh (14.958 kWh/day) 6.403 kWh (1.142 kWh/day)
  - This Year 1.307 MWh (13.669 kWh/day) 1.649 MWh (17.250 kWh/day) 0.342 MWh (3.581 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 104.298 kWh (14.900 kWh/day) 101.504 kWh (14.501 kWh/day) -2.794 kWh (-0.399 kWh/day)
Last 30 Days (03/07/2026) 581.541 kWh (19.385 kWh/day) 450.764 kWh (15.025 kWh/day) -130.777 kWh (-4.359 kWh/day)
Last One Year 6.120 MWh (16.767 kWh/day) 7.836 MWh (21.469 kWh/day) 1.716 MWh (4.702 kWh/day)
Lifetime Since PTO 36.873 MWh (17.225 kW/day) 41.160 MWh (19.228 kW/day) 4.287 MWh (2.003 kW/day)
Lifetime Since Install 36.906 MWh 41.740 MWh 4.833 MWh
Voltage/Current 251.7 V / 16.1 A 251.6 V / -5.9 A 251.6 V / -22.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/05/2025 23:57 (9.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.026 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.220 0.631 0.897 4.654 0.000 kW
0.626 kWh
0.000 kW
3.753 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.223 0.606 0.843 4.407
03 - 202224****** IQ7+M [5] VCOP 0.000 0.228 0.647 0.883 4.606
04 - 202232****** IQ7+ [5] VCOP 0.000 0.229 0.651 0.880 4.621
05 - 202244****** IQ7+M [5] VCOP 0.000 0.222 0.612 0.843 4.390
06 - 202245****** IQ7+M [5] VCOP 0.000 0.225 0.607 0.860 4.475
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.281 0.794 0.917 4.717 0.000 kW
0.818 kWh
0.000 kW
4.091 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 0.805 0.992 5.195
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 0.829 1.018 5.426
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 0.830 1.018 5.360
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 0.833 0.988 5.116
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.078 0.263 0.426 2.266 0.000 kW
0.295 kWh
0.000 kW
1.182 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.095 0.298 0.490 2.542
14 - 202216****** IQ7+ [5] VCOP 0.000 0.097 0.311 0.509 2.645
15 - 202245****** IQ7+M [5] VCOP 0.000 0.094 0.310 0.504 2.605
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Charger History
Voltage PV 0.53 V Voltage Charge 51.85 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 24.1 °C / 21.6 °C Flags 00/00/00 Energy Today 2.429 kWh @ 2025-01-05 23:55
voltage in/out power and energy
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary.png". Check that the process running PHP has enough permission.