Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.334 kW
05/22/2026 21:45 (2186 days) Production Consumption NET Usage
Now 0.000 kW 0.334 kW 0.334 kW
Today 29.595 kWh (1.359 kW) 4.493 kWh (0.206 kW) -25.102 kWh (-1.153 kW)
  - This Week 155.372 kWh (26.302 kWh/day) 148.657 kWh (25.165 kWh/day) -6.715 kWh (-1.137 kWh/day)
  - This Month 557.188 kWh (25.435 kWh/day) 348.379 kWh (15.903 kWh/day) -208.809 kWh (-9.532 kWh/day)
  - This Year 2.510 MWh (17.689 kWh/day) 2.408 MWh (16.970 kWh/day) -0.102 MWh (-0.720 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.233 kWh (22.319 kWh/day) -32.057 kWh (-4.580 kWh/day)
Last 30 Days (04/22/2026) 721.023 kWh (24.034 kWh/day) 419.933 kWh (13.998 kWh/day) -301.090 kWh (-10.036 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.790 MWh (21.342 kWh/day) 1.398 MWh (3.830 kWh/day)
Lifetime Since PTO 38.076 MWh (17.411 kW/day) 41.919 MWh (19.168 kW/day) 3.843 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.499 MWh 4.389 MWh
Voltage/Current 249.1 V / 0.0 A 248.9 V / 1.3 A 249.0 V / 1.3 A
Meter

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 10/05/2025 23:57 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 26.831 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.231 1.538 1.612 10.625 0.000 kW
1.499 kWh
0.000 kW
8.994 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.221 1.471 1.538 10.159
03 - 202224****** IQ7+M [0] ---- 0.000 0.229 1.520 1.587 10.496
04 - 202232****** IQ7+ [0] ---- 0.000 0.233 1.536 1.598 10.579
05 - 202244****** IQ7+M [0] ---- 0.000 0.223 1.453 1.512 9.999
06 - 202245****** IQ7+M [0] ---- 0.000 0.226 1.476 1.540 10.205
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.256 1.517 1.563 10.366 0.000 kW
1.650 kWh
0.000 kW
8.252 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.261 1.662 1.717 11.239
09 - 202217****** IQ7+ [0] ---- 0.000 0.258 1.679 1.740 11.309
10 - 202244****** IQ7+M [0] ---- 0.000 0.257 1.686 1.741 11.322
11 - 202224****** IQ7+M [0] ---- 0.000 0.263 1.708 1.766 11.470
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.155 0.967 1.039 7.220 0.000 kW
1.022 kWh
0.000 kW
4.087 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.159 1.019 1.089 7.512
14 - 202216****** IQ7+ [0] ---- 0.000 0.161 1.052 1.121 7.755
15 - 202245****** IQ7+M [0] ---- 0.000 0.161 1.048 1.116 7.744
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.749 kWh
0.230 kW
5.498 kWh
17 - 122214****** IQ7PD [0] ---- 0.230 0.230 5.498 5.503 35.293
Panel Layout Each Group Production

Charger History
Voltage PV 1.49 V Voltage Charge 52.84 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 30.8 °C / 28.2 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-10-05 23:59
voltage in/out power and energy

Battery History
Voltage 53.12 V Current/Power -6.29 A (-0.334 kW)
Remain Capacity/Energy 486.2 Ah (24.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 82.0 % State Of Health 98.9 %
Run Time 3d 5h 17m to empty Report Date 2025-10-05 23:56
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.