Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 4.108 kW
04/10/2026 13:00 (2144 days) Production Consumption NET Usage
Now 4.339 kW 0.231 kW -4.108 kW
Today 17.376 kWh (1.332 kW) 40.518 kWh (3.106 kW) 23.142 kWh (1.774 kW)
  - This Week 167.252 kWh (30.178 kWh/day) 110.507 kWh (19.939 kWh/day) -56.745 kWh (-10.239 kWh/day)
  - This Month 219.857 kWh (23.040 kWh/day) 171.566 kWh (17.979 kWh/day) -48.291 kWh (-5.061 kWh/day)
  - This Year 1.449 MWh (14.559 kWh/day) 1.737 MWh (17.449 kWh/day) 0.288 MWh (2.890 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 198.643 kWh (28.378 kWh/day) 134.924 kWh (19.275 kWh/day) -63.719 kWh (-9.103 kWh/day)
Last 30 Days (03/11/2026) 653.539 kWh (21.785 kWh/day) 482.417 kWh (16.081 kWh/day) -171.122 kWh (-5.704 kWh/day)
Last One Year 6.183 MWh (16.939 kWh/day) 7.864 MWh (21.544 kWh/day) 1.681 MWh (4.605 kWh/day)
Lifetime Since PTO 37.015 MWh (17.260 kW/day) 41.248 MWh (19.234 kW/day) 4.233 MWh (1.974 kW/day)
Lifetime Since Install 37.049 MWh 41.828 MWh 4.779 MWh
Voltage/Current 251.5 V / 17.2 A 251.6 V / 0.9 A 251.6 V / -16.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/08/2020 22:48 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.655 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.291 1.302 1.093 12.058 0.000 kW
1.286 kWh
0.000 kW
7.715 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.288 1.037 11.713
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.300 1.045 11.725
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.295 1.039 11.759
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.245 1.005 10.882
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.285 1.056 11.792
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.281 1.138 0.957 10.585 0.000 kW
1.169 kWh
0.000 kW
5.845 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.172 0.956 10.914
09 - 202217****** IQ7+ [5] VCOP 0.000 0.275 1.153 0.970 10.778
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 1.195 0.976 10.988
11 - 202224****** IQ7+M [5] VCOP 0.000 0.274 1.186 0.968 10.950
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.270 1.192 11.804 0.000 kW
1.274 kWh
0.000 kW
5.095 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.282 1.266 1.197 11.584
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 1.286 1.209 11.858
15 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.273 1.196 11.658
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.97 A (10.368 kW)
Remain Capacity/Energy 576.0 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.8 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-08 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.