Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.080 kW
05/25/2026 11:04 (2189 days) Production Consumption NET Usage
Now 0.841 kW 0.761 kW -0.080 kW
Today 2.467 kWh (0.222 kW) 4.671 kWh (0.421 kW) 2.204 kWh (0.198 kW)
  - This Week 9.181 kWh (6.280 kWh/day) 14.540 kWh (9.946 kWh/day) 5.359 kWh (3.666 kWh/day)
  - This Month 571.176 kWh (23.350 kWh/day) 370.709 kWh (15.155 kWh/day) -200.467 kWh (-8.195 kWh/day)
  - This Year 2.524 MWh (17.473 kWh/day) 2.430 MWh (16.824 kWh/day) -0.094 MWh (-0.649 kWh/day)
Yesterday 6.714 kWh (0.280 kW) 9.869 kWh (0.412 kW) 3.155 kWh (0.132 kW)
Last 7 Days 130.661 kWh (18.666 kWh/day) 142.322 kWh (20.332 kWh/day) 11.661 kWh (1.666 kWh/day)
Last 30 Days (04/25/2026) 677.069 kWh (22.569 kWh/day) 425.310 kWh (14.177 kWh/day) -251.759 kWh (-8.392 kWh/day)
Last One Year 6.364 MWh (17.436 kWh/day) 7.777 MWh (21.308 kWh/day) 1.413 MWh (3.872 kWh/day)
Lifetime Since PTO 38.090 MWh (17.397 kW/day) 41.941 MWh (19.156 kW/day) 3.851 MWh (1.759 kW/day)
Lifetime Since Install 38.124 MWh 42.521 MWh 4.397 MWh
Voltage/Current 248.3 V / 3.4 A 248.3 V / 3.1 A 248.3 V / -0.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/19/2020 21:46 (9.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.067 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.249 0.933 1.015 4.381 0.000 kW
0.916 kWh
0.000 kW
5.494 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.248 0.916 1.004 4.390
03 - 202224****** IQ7+M [5] VCOP 0.000 0.249 0.917 1.012 4.417
04 - 202232****** IQ7+ [5] VCOP 0.000 0.249 0.881 0.985 4.280
05 - 202244****** IQ7+M [5] VCOP 0.000 0.251 0.925 1.022 4.312
06 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.923 1.003 4.153
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.072 1.185 4.969 0.000 kW
1.094 kWh
0.000 kW
5.471 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.008 1.131 4.526
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.149 1.308 5.439
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.145 1.284 5.377
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.096 1.205 5.086
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.127 0.503 0.452 2.475 0.000 kW
0.526 kWh
0.000 kW
2.102 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.128 0.539 0.519 2.698
14 - 202216****** IQ7+ [5] VCOP 0.000 0.129 0.537 0.511 2.614
15 - 202245****** IQ7+M [5] VCOP 0.000 0.127 0.524 0.496 2.604
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.45 V Current/Power 163.79 A (8.590 kW)
Remain Capacity/Energy 324.9 Ah (16.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 55.0 % State Of Health 98.5 %
Run Time 1h 37m to full Report Date 2020-11-18 17:58
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.45 V Cell (MIN/MAX) 3.272 V / 3.282 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 9d 0h 36m to empty
Remain Capacity/Energy 108.3 Ah (5.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 55.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-18 17:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.272 V 3.273 V 3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.278 V 3.278 V 3.279 V 3.279 V 3.281 V 3.281 V 3.281 V 3.282 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -