Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.011 kW
05/24/2026 16:25 (2188 days) Production Consumption NET Usage
Now 0.471 kW 0.460 kW -0.011 kW
Today 5.827 kWh (0.355 kW) 4.844 kWh (0.295 kW) -0.983 kWh (-0.060 kW)
  - This Week 5.827 kWh (8.515 kWh/day) 4.844 kWh (7.078 kWh/day) -0.983 kWh (-1.436 kWh/day)
  - This Month 567.822 kWh (23.975 kWh/day) 361.013 kWh (15.243 kWh/day) -206.809 kWh (-8.732 kWh/day)
  - This Year 2.521 MWh (17.544 kWh/day) 2.421 MWh (16.848 kWh/day) -0.100 MWh (-0.697 kWh/day)
Yesterday 4.807 kWh (0.200 kW) 7.178 kWh (0.299 kW) 2.371 kWh (0.099 kW)
Last 7 Days 138.810 kWh (19.830 kWh/day) 155.006 kWh (22.144 kWh/day) 16.196 kWh (2.314 kWh/day)
Last 30 Days (04/24/2026) 679.345 kWh (22.645 kWh/day) 421.485 kWh (14.050 kWh/day) -257.860 kWh (-8.595 kWh/day)
Last One Year 6.370 MWh (17.451 kWh/day) 7.778 MWh (21.309 kWh/day) 1.408 MWh (3.857 kWh/day)
Lifetime Since PTO 38.087 MWh (17.402 kW/day) 41.931 MWh (19.158 kW/day) 3.845 MWh (1.757 kW/day)
Lifetime Since Install 38.120 MWh 42.511 MWh 4.391 MWh
Voltage/Current 248.7 V / 1.9 A 248.6 V / 1.9 A 248.6 V / -0.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/06/2021 22:00 (9.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.824 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.228 1.085 1.206 6.511 0.000 kW
1.049 kWh
0.000 kW
6.297 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.223 1.012 1.123 6.025
03 - 202224****** IQ7+M [5] VCOP 0.000 0.227 1.080 1.214 6.399
04 - 202232****** IQ7+ [5] VCOP 0.000 0.226 1.034 1.168 6.181
05 - 202244****** IQ7+M [5] VCOP 0.000 0.225 1.066 1.206 6.365
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 1.019 1.162 6.177
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 1.183 1.456 7.366 0.000 kW
1.204 kWh
0.000 kW
6.021 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.031 1.280 6.671
09 - 202217****** IQ7+ [5] VCOP 0.000 0.277 1.315 1.602 7.778
10 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.271 1.581 7.650
11 - 202224****** IQ7+M [5] VCOP 0.000 0.274 1.220 1.513 7.517
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.127 0.589 0.637 3.974 0.000 kW
0.627 kWh
0.000 kW
2.506 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.640 0.699 4.167
14 - 202216****** IQ7+ [5] VCOP 0.000 0.129 0.645 0.704 4.217
15 - 202245****** IQ7+M [5] VCOP 0.000 0.126 0.632 0.690 4.142
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.